Suppr超能文献

用于对家禽、肉类和海鲜中经确认的大肠杆菌进行计数的干可再水化膜法:协作研究

Dry rehydratable film method for enumerating confirmed Escherichia coli in poultry, meats, and seafood: collaborative study.

作者信息

Gangar V, Curiale M S, Lindberg K, Gambrel-Lenarz S

机构信息

Silliker Laboratories Group, Inc., Corporate Research Center, South Holland, IL 60473, USA.

出版信息

J AOAC Int. 1999 Jan-Feb;82(1):73-8.

Abstract

A rehydratable dry-film plating method for Escherichia coli, the Petrifilm E. coli/Coliform (EC) Count Plate in foods, has been compared with the AOAC INTERNATIONAL most probable number (MPN) method. Eleven laboratories participated in the collaborative study. Three E. coli levels in 8 samples each of frozen raw ground turkey, frozen raw ground beef, and frozen cooked fish were tested in duplicate. Mean log counts for the Petrifilm plate procedure were not significantly different from those for the MPN procedure for cooked fish samples inoculated with low or high inocula levels, for samples of raw turkey inoculated at medium level, and for beef inoculated at low, medium, and high levels. Repeatability and reproducibility variances of the Petrifilm EC Plate method recorded at 24 h were as good as or better than those of the MPN method. The dry rehydratable film method for enumerating confirmed E. coli in poultry, meats, and seafood has been adopted first action by AOAC INTERNATIONAL.

摘要

一种用于检测大肠杆菌的可复水干膜平板法——食品中的Petrifilm大肠杆菌/大肠菌群(EC)计数平板,已与美国官方分析化学师协会(AOAC INTERNATIONAL)的最大可能数(MPN)法进行了比较。11个实验室参与了这项协作研究。对冷冻生火鸡肉末、冷冻生牛肉末和冷冻熟鱼各8个样本中的三种大肠杆菌水平进行了重复检测。对于接种低接种量或高接种量的熟鱼样本、接种中等接种量的生火鸡肉样本以及接种低、中、高接种量的牛肉样本,Petrifilm平板法的平均对数计数与MPN法的平均对数计数没有显著差异。在24小时记录的Petrifilm EC平板法的重复性和再现性方差与MPN法的一样好或更好。用于在禽肉、肉类和海鲜中计数确诊大肠杆菌的可复水干膜法已被AOAC INTERNATIONAL首次采用。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验