Abstract

During the development of the microtensile bond-testing method, large variations in bond strengths were noted among serial sections. The reason for these variations is unknown. The purpose of this work was to determine the consistency of resin-dentin bond strengths across the occlusal surface of coronal dentin by dividing composite resin buildups into an array of 1x1 mm beams, the top half consisting of composite resin, and the bottom half consisting of dentin. Extracted human third molars had the occlusal enamel removed as a single section by means of a diamond saw. Resin composite buildups were made after the dentin was bonded with either One-Step or MacBond. After being stored in 37 degrees C water for 1 day, the teeth were vertically sectioned at 1-mm increments into slabs of bonded teeth. Each slab was further subdivided by vertical sections into 1x1x8 mm beams. Each beam was assigned an x-y coordinate and tested for tensile bond strength. Two different clinicians (A and B) performed the same procedures using One-Step in a parallel study. Using One-Step, clinician A obtained a large number of zero bonds in superficial dentin but fewer in deep dentin. This resulted in a very large standard deviation in bond strengths (mean +/- SD of 22+/-20 MPa in superficial dentin and 27+/-14 MPa in deep dentin). Clinician B obtained much higher (p<0.001) and more uniform bond strengths with One-Step (56+/-13 MPa in superficial dentin and 57+/-12 MPa in deep dentin). With MacBond, there were no zero bonds and hence less variation, with a mean of 41+/-13 MPa in superficial dentin and 27+/-12 MPa (x +/- SD) in deep dentin. When pairs of Z100 resin composite cylinders were bonded together with One-Step and then sectioned into an array, there was little variation in regional bond strength (37 +/-1 MPa). Dividing bonded resin composite buildups into an array of 20 to 30 1x1x8 mm beams allows for the evaluation of uniformity of resin-dentin bonds. The method used in this study detected local regional differences in resin-dentin bond strengths. The largest differences were shown to be related to technique rather than to material. The results indicate that resin-dentin bonds may not be as homogenous as was previously thought.

摘要

在微拉伸粘结测试方法的研发过程中,研究人员注意到连续切片之间的粘结强度存在很大差异。这些差异的原因尚不清楚。本研究的目的是通过将复合树脂堆积物划分为一系列1×1毫米的梁来确定冠部牙本质咬合面树脂-牙本质粘结强度的一致性,梁的上半部分由复合树脂组成,下半部分由牙本质组成。用金刚石锯将拔除的人类第三磨牙的咬合面釉质作为一个整体切片去除。在用单步粘结剂(One-Step)或MacBond粘结牙本质后制作树脂复合材料堆积物。在37℃水中储存1天后,将牙齿以1毫米的增量垂直切片成粘结牙齿的薄片。每个薄片再通过垂直切片细分为1×1×8毫米的梁。为每根梁指定一个x-y坐标,并测试其拉伸粘结强度。在一项平行研究中,两名不同的临床医生(A和B)使用单步粘结剂进行相同的操作。使用单步粘结剂时,临床医生A在表层牙本质中获得了大量零粘结,但在深层牙本质中较少。这导致粘结强度的标准差非常大(表层牙本质中平均±标准差为22±20兆帕,深层牙本质中为27±14兆帕)。临床医生B使用单步粘结剂获得的粘结强度要高得多(p<0.001)且更均匀(表层牙本质中为56±13兆帕,深层牙本质中为57±12兆帕)。使用MacBond时,没有零粘结,因此差异较小,表层牙本质中的平均值为41±13兆帕,深层牙本质中的平均值为27±12兆帕(x±标准差)。当用单步粘结剂将成对的Z100树脂复合材料圆柱体粘结在一起,然后切成阵列时,区域粘结强度几乎没有差异(37±1兆帕)。将粘结的树脂复合材料堆积物划分为20至30个1×1×8毫米的梁阵列,可以评估树脂-牙本质粘结的均匀性。本研究中使用的方法检测到了树脂-牙本质粘结强度的局部区域差异。最大的差异表明与技术而非材料有关。结果表明,树脂-牙本质粘结可能不像以前认为的那样均匀。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验