Suppr超能文献

感兴趣区绘制中的操作者内和操作者间差异及其对肾小球滤过率测量的影响。

Intra- and interoperator variations in region-of-interest drawing and their effect on the measurement of glomerular filtration rates.

作者信息

White D R, Houston A S, Sampson W F, Wilkins G P

机构信息

Department of Nuclear Medicine, Royal Hospital Haslar, Gosport, Hampshire, United Kingdom.

出版信息

Clin Nucl Med. 1999 Mar;24(3):177-81. doi: 10.1097/00003072-199903000-00008.

Abstract

PURPOSE

Quantitative results are often obtained from images after drawing regions of interest (ROIs) about the organ or area being evaluated. The accuracy and reproducibility of ROIs is an important aspect of quality-control protocols. Attempts to increase ROI accuracy and precision by generating them automatically must be compared with manually processed images to evaluate the success of the automatic methods. Operators' abilities to reproduce ROIs and the effect this has on the reproducibility of estimating glomerular filtration rate from renograms were assessed.

METHODS

Estimation of the glomerular filtration rate using Sampson's method requires a) exclusion ROIs around both kidneys for background subtraction, b) whole-kidney ROIs, and c) exclusion ROIs for the collecting system. Two nuclear medicine professionals were asked to produce glomerular filtration rate estimates for 20 patients with diverse renal function. This was repeated 1 month later. The intra- and interoperator variations were calculated for the glomerular filtration rate results and on a pixel basis for the ROIs.

RESULTS

THE percentage of common pixels, on average, for a) intraoperator repeats and b) interoperator comparisons were a) 95%, 94%, 85%, and b) 94%, 93%, and 81% for region types 1, 2, and, 3, respectively. Analysis of variance for the glomerular filtration rate estimates showed significant variations in estimates for left kidneys (P < 0.025) but none (P > 0.1) for right kidneys.

CONCLUSION

Spatial reproducibility in ROI drawing does not necessarily relate directly to the associated quantitative reproducibility.

摘要

目的

定量结果通常是在围绕被评估器官或区域绘制感兴趣区(ROI)后从图像中获得的。ROI的准确性和可重复性是质量控制方案的一个重要方面。通过自动生成ROI来提高其准确性和精确性的尝试必须与手动处理的图像进行比较,以评估自动方法的成功与否。评估了操作人员重现ROI的能力以及这对从肾图估计肾小球滤过率的可重复性的影响。

方法

使用桑普森方法估计肾小球滤过率需要:a)围绕双肾绘制排除ROI以进行背景减除,b)绘制全肾ROI,以及c)绘制收集系统的排除ROI。两名核医学专业人员被要求为20名肾功能各异的患者估计肾小球滤过率。1个月后重复此操作。计算了肾小球滤过率结果以及ROI在像素基础上的操作者内和操作者间变异。

结果

对于a)操作者内重复和b)操作者间比较,区域类型1、2和3的平均共同像素百分比分别为:a)95%、94%、85%,以及b)94%、93%和81%。肾小球滤过率估计值的方差分析显示,左肾估计值存在显著差异(P<0.025),而右肾无显著差异(P>0.1)。

结论

ROI绘制中的空间可重复性不一定直接与相关的定量可重复性相关。