In suspected adrenal insufficiency, the ideal test for assessing the hypothalamo-pituitary-adrenal axis is controversial. Therefore, three tests were compared in patients presenting with symptoms suggestive of adrenal insufficiency.
Responses to the standard short Synacthen test (SSST), the low dose Synacthen test (LDST), and the 08:00 hour serum cortisol concentration were measured in 32 patients. A normal response to the synacthen test was defined as a peak serum cortisol of >/= 500 nmol/l and/or incremental concentration of >/= 200 nmol/l. The sensitivity and specificity of the 08:00 hour serum cortisol concentration compared with other tests was calculated.
Three patients had neither an adequate peak nor increment after the SSST and LDST. All had a serum 08:00 hour cortisol concentration of < 200 nmol/l. Eight patients had abnormal responses by both criteria to the LDST but had normal responses to the SSST. Three reported amelioration of their symptoms on hydrocortisone replacement. Twenty one patients had a normal response to both tests (of these, 14 achieved adequate peak and increment after both tests and seven did not have an adequate peak after the LDST but had a normal increment). The lowest 08:00 hour serum cortisol concentration above which patients achieved normal responses to both the LDST and SSST was 500 nmol/l. At this cut off value (compared with the LDST), the serum 08:00 hour cortisol concentration had a sensitivity of 100% but specificity was only 33%.
The LDST revealed mild degrees of adrenal insufficiency not detected by the SSST. The value of a single 08:00 hour serum cortisol concentration is limited.
在疑似肾上腺功能不全的情况下,评估下丘脑 - 垂体 - 肾上腺轴的理想检测方法存在争议。因此,对有肾上腺功能不全症状的患者进行了三种检测方法的比较。
对32例患者测量了对标准短程促肾上腺皮质激素试验(SSST)、低剂量促肾上腺皮质激素试验(LDST)以及上午8点血清皮质醇浓度的反应。促肾上腺皮质激素试验的正常反应定义为血清皮质醇峰值≥500 nmol/l和/或增量浓度≥200 nmol/l。计算上午8点血清皮质醇浓度与其他检测方法相比的敏感性和特异性。
3例患者在SSST和LDST后既无足够的峰值也无增量。所有患者上午8点血清皮质醇浓度均<200 nmol/l。8例患者根据两种标准对LDST反应异常,但对SSST反应正常。3例报告在氢化可的松替代治疗后症状改善。21例患者对两种检测均反应正常(其中,14例在两种检测后均达到足够的峰值和增量,7例在LDST后没有足够的峰值但增量正常)。患者对LDST和SSST均反应正常的最低上午8点血清皮质醇浓度为500 nmol/l。在此临界值(与LDST相比)时,上午8点血清皮质醇浓度敏感性为100%,但特异性仅为33%。
LDST揭示了SSST未检测到的轻度肾上腺功能不全。单次上午8点血清皮质醇浓度的价值有限。