Martinez-Alonso J R, Zunzunegui-Pastor V, Marin-Rojas M C, Moreno-Gonzalez J, Millan-Santos I, Martinez-Sales V, Ortiz-Berrocal J
Comput Programs Biomed. 1976 Dec;6(4):249-62. doi: 10.1016/0010-468x(76)90041-6.
A method is devised for the automatic computation of data obtained from a series of determinations by radioimmunoassay or by competitive protein binding. The input data is introduced by means of an automatic paper tape punch attached to the sample counter. A series of programs is set up for a Hewlett Packard computer, model 2116B with 16K, which calculates bound and free fractions with control processes for varying possible errors. From experimental data, by linear least squares regression, a standard curve of best fit is derived and is considered in three different ways. The curve of best fit is selected by comparing the correlation coefficients obtained and by calculating the unknown sample concentrations. The program presents the results graphically together with a list of results which is for use within the Radiochemistry laboratory. Individual reports are also prepared for sending to those departments that requested the test.
设计了一种用于自动计算通过放射免疫测定法或竞争性蛋白结合法从一系列测定中获得的数据的方法。输入数据通过连接到样品计数器的自动纸带穿孔机输入。为配备16K内存的惠普2116B型计算机设置了一系列程序,该程序可计算结合和游离部分,并对各种可能的误差进行控制处理。通过线性最小二乘法回归从实验数据中得出最佳拟合标准曲线,并以三种不同方式进行考量。通过比较获得的相关系数并计算未知样品浓度来选择最佳拟合曲线。该程序以图形方式呈现结果以及一份结果列表,供放射化学实验室内使用。还会准备单独的报告发送给那些要求进行测试的部门。