使用抗醛固酮-γ-内酯抗血清的醛固酮简易放射免疫测定法。

Simplified radioimmunoassay for aldosterone using antisera to aldosterone-gamma-lactone.

作者信息

Antunes J R, Dale S L, Melby J C

出版信息

Steroids. 1976 Nov;28(5):621-30. doi: 10.1016/0039-128x(76)90004-0.

Abstract

A simplified, non-chromatographic method for aldosterone-gamma-lactone (2) radio-immunoassay is described, using a high titer aldosterone-gamma-lactone antibody. This method takes six working hours for completion; the blanks are below the sensitivity of the assay (0-10 pg), and the intra and interassay coefficient of variation is 4.9% and 8.2% respectively. There is no significant variation with different plasma volumes assayed and the plot of added and assayed aldosterone gives a slope of 0.983. The negligible cross reactivity with other steroids and lactones eliminates the problem of interference by these substances.

摘要

描述了一种使用高滴度醛固酮 - γ - 内酯抗体的简化非色谱法,用于醛固酮 - γ - 内酯(2)的放射免疫测定。该方法完成需要六个工作小时;空白值低于测定灵敏度(0 - 10皮克),批内和批间变异系数分别为4.9%和8.2%。测定不同血浆体积时无显著差异,添加和测定的醛固酮的曲线斜率为0.983。与其他类固醇和内酯的交叉反应可忽略不计,消除了这些物质干扰的问题。