Suppr超能文献

无领楔形假体在股骨髓腔内的初始稳定性。

Initial stability of a collarless wedge-shaped prosthesis in the femoral canal.

作者信息

Sharkey P F, Albert T J, Hume E L, Rothman R H

机构信息

Departments of Orthopaedics, Thomas Jefferson University, Philadelphia, PA.

出版信息

Semin Arthroplasty. 1990 Jul;1(1):87-90.

Abstract

A collarless wedge-shaped implant was inserted with cementless technique in seven fresh-frozen adult femora. Micromotion of the implant in the proximal femur was evaluated by applying an axial load of 3,000 N or a rotational force of 12 Nm. Six femurs were prepared using a cemented implant, and their stability was similarly determined for comparative purposes. In all tests, the amount of plastic deformation after load relief was quantitated. The cementless prosthesis had excellent initial stability with axial and rotational loading; also the micromotion was similar to that of the cemented implant. Deformation under these experimental conditions was predominantly elastic. The stability demonstrated with this cementless prosthesis satisfies the conditions necessary for bone ingrowth in vivo.

摘要

采用非骨水泥技术将无领楔形植入物植入七具新鲜冷冻的成年股骨中。通过施加3000N的轴向载荷或12Nm的旋转力来评估植入物在股骨近端的微动情况。使用骨水泥固定植入物制备六具股骨,并出于比较目的以类似方式确定其稳定性。在所有测试中,均对卸载后的塑性变形量进行了定量。非骨水泥假体在轴向和旋转加载时具有出色的初始稳定性;其微动情况也与骨水泥固定植入物相似。在这些实验条件下的变形主要是弹性的。这种非骨水泥假体所展示的稳定性满足了体内骨长入所需的条件。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验