Gas-powered and portable ventilators: an evaluation of six models.

作者信息

Nolan J P, Baskett P J

机构信息

Royal United Hospital, Bath, United Kingdom.

出版信息

Prehosp Disaster Med. 1992 Jan-Mar;7(1):25-34. doi: 10.1017/s1049023x00039169.

DOI:10.1017/s1049023x00039169
PMID:10149692
Abstract

INTRODUCTION

Gas-powered resuscitators (ventilators) designed to be used primarily for resuscitation should be basic and simple to use. They offer many advantages over manual methods of ventilation during in-hospital cardiopulmonary resuscitation. Portable ventilators intended for critical care transport require additional, more sophisticated features such as: adjustable pressure limiting valves, air-mixing, airway pressure gauge, independent tidal volume and rate controls, and a Positive End-Expiratory Pressure (PEEP) valve. The performance of six gas-powered resuscitators/portable ventilators (TransPAC, Oxylog, Ambu Matic, ERA 2000, Uni-Vent, and MARS) was evaluated.

METHODS

The accuracy of volumes delivered to a test lung at three different compliance and resistance settings, was assessed for each ventilator prior to clinical evaluation during cardio-pulmonary resuscitation (CPR) and patient transport.

RESULTS

In each circumstance, measured tidal volumes and level of minute ventilation decreased as resistance was increased and compliance reduced. Much of this loss of measured tidal volume occurred through inspiratory pressure relief valves that tended to start leaking at pressures below the preset level. Increasing levels of back-pressure resulted in further reductions in tidal volume when the ventilators were tested using the air-mix mode (available on three of the devices). In general, each resuscitator functioned well when used during CPR within the hospital.

CONCLUSIONS

Each resuscitator tested failed to deliver the preset volumes and this must be considered during their use. Inspiratory pressure relief valves for all but one of the ventilators tested would not permit the delivery of adequate levels of ventilation in patients with low pulmonary compliance and/or high airway resistance.

摘要

相似文献

1
Gas-powered and portable ventilators: an evaluation of six models.
Prehosp Disaster Med. 1992 Jan-Mar;7(1):25-34. doi: 10.1017/s1049023x00039169.
2
Battery duration of portable ventilators: effects of control variable, positive end-expiratory pressure, and inspired oxygen concentration.便携式呼吸机的电池续航时间:控制变量、呼气末正压和吸入氧浓度的影响。
Respir Care. 2002 Oct;47(10):1173-83.
3
Passive continuous positive airway pressure ventilation during cardiopulmonary resuscitation: a randomized cross-over manikin simulation study.心肺复苏期间的被动持续气道正压通气:一项随机交叉人体模型模拟研究。
J Clin Monit Comput. 2017 Feb;31(1):93-101. doi: 10.1007/s10877-016-9836-6. Epub 2016 Feb 9.
4
Do new anesthesia ventilators deliver small tidal volumes accurately during volume-controlled ventilation?新型麻醉呼吸机在容量控制通气期间能否准确输送小潮气量?
Anesth Analg. 2008 May;106(5):1392-400, table of contents. doi: 10.1213/ane.0b013e31816a68c6.
5
Artificial ventilation during transport: A randomized crossover study of manual resuscitators with comparison to mechanical ventilators in a simulation model.转运期间的人工通气:在模拟模型中对人工复苏器与机械通气机进行比较的随机交叉研究。
Paediatr Anaesth. 2018 Sep;28(9):788-794. doi: 10.1111/pan.13389.
6
Manual resuscitators and spontaneous ventilation--an evaluation.手动复苏器与自主通气——一项评估。
Crit Care Med. 1991 Nov;19(11):1425-31. doi: 10.1097/00003246-199111000-00020.
7
[Mechanical ventilation in an anesthetic circle system using the lowest tidal volume--studies of 3 anesthesia ventilators in a lung model and an animal experiment].[在麻醉环路系统中使用最低潮气量进行机械通气——在肺模型和动物实验中对3种麻醉呼吸机的研究]
Anaesthesist. 1991 Nov;40(11):624-8.
8
Evaluation of 16 adult disposable manual resuscitators.16款成人一次性手动复苏器的评估
Respir Care. 2004 Dec;49(12):1509-14.
9
Reliability of mechanical ventilation during continuous chest compressions: a crossover study of transport ventilators in a human cadaver model of CPR.连续胸外按压期间机械通气的可靠性:心肺复苏人体模型中转运呼吸机的交叉研究。
Scand J Trauma Resusc Emerg Med. 2021 Jul 28;29(1):102. doi: 10.1186/s13049-021-00921-2.
10
Evaluation of the Pneupac Ventipac portable ventilator: comparison of performance in a mechanical lung and anaesthetized patients.
Br J Anaesth. 1995 Nov;75(5):645-50. doi: 10.1093/bja/75.5.645.

引用本文的文献

1
Use of a gas-operated ventilator as a noninvasive bridging respiratory therapy in critically Ill COVID-19 patients in a middle-income country.在一个中等收入国家,使用气动呼吸机作为重症新冠肺炎患者的无创过渡性呼吸治疗手段。
Intern Emerg Med. 2025 Mar;20(2):543-551. doi: 10.1007/s11739-024-03681-w. Epub 2024 Jun 28.