Affinity pump system: a new peristaltic blood pump for cardiopulmonary bypass.

作者信息

Jaggy C, Lachat M, Leskosek B, Zünd G, Turina M

机构信息

Clinic for Cardiovascular Surgery, University Hospital, Zurich, Switzerland.

出版信息

Perfusion. 2000 Jan;15(1):77-83. doi: 10.1177/026765910001500111.

DOI:10.1177/026765910001500111
PMID:10676871
Abstract

An in vitro study has been carried out to assess the pump performance of a new peristaltic, extracorporeal displacement pump (Affinity) for cardiopulmonary bypass. The pump system consists of a pump rotor (0-110 rpm), a pump chamber, a venous reservoir with a 5/8" connecting tube and the Affinity console. The polyurethane chamber is connected to the venous reservoir by a 5/8" tube and fills passively due to the hydrostatic pressure exhibited by the fluid height in the venous reservoir. The implementation of an occlusive segment in the pump chamber, which collapses in low filling states, should prevent significant negative pressures. An in vitro circuit was filled with bovine blood (37 degrees C, hematocrit 35%) and the pump flow was measured by an ultrasonic transit time flow probe with respect to pre-load, diameter and length of attached tubing in the venous line, pump speed (rpm) and size of the connecting tube (3/8" and 5/8"). At 108 rpm and a preload equal to 10 mmHg, the flow was 8.6 +/- 0.42 l/min for an afterload of 80 mmHg. The reduction of the inlet connector to 3/8" diminished the pump flow significantly to 5.2 +/- 0.31 l/min (p < 0.0001). The pump flow decreased linearly with respect to the length of the attached tube in the venous line and for a 2 m long 5/8" silicon tube, the rpm-optimized flow was still 6.0 +/- 0.28 l/min at a preload of 10 mmHg. In case of low filling state or too high rpm, the occlusive segment collapsed and no cavitation bubbles could be detected. Our in vitro measurements yield a nomogram for rpm-optimized blood flow with respect to the pre-load in the venous reservoir. The delivered 5/8"connecting tube facilitates optimum filling of the pump chamber for high blood flow, but limits the use of venous reservoirs to Affinity products. The pump yields a high blood flow even when long tubing in the venous line is used. This makes the pump a candidate for a ventricular assist device. In hypovolemia or high rpm, the occlusive segment collapses and no negative pressure is generated at the inflow site of the pump chamber.

摘要

相似文献

1
Affinity pump system: a new peristaltic blood pump for cardiopulmonary bypass.
Perfusion. 2000 Jan;15(1):77-83. doi: 10.1177/026765910001500111.
2
Significant safety advantages gained with an improved pressure-regulated blood pump.改进后的压力调节血泵具有显著的安全优势。
J Extra Corpor Technol. 1996 Jun;28(2):71-8.
3
Superior flow for bridge to life with self-expanding venous cannulas.带自膨式静脉插管的桥接生命的高流量。
Eur J Cardiothorac Surg. 2009 Oct;36(4):665-9. doi: 10.1016/j.ejcts.2009.05.026. Epub 2009 Jul 16.
4
Efficacy and safety of strategies to preserve stable extracorporeal life support flow during simulated hypovolemia.
Perfusion. 2014 Jan;29(1):18-24. doi: 10.1177/0267659113502833. Epub 2013 Aug 28.
5
Mechanical performance comparison between RotaFlow and CentriMag centrifugal blood pumps in an adult ECLS model.在成人体外膜肺氧合(ECLS)模型中,RotaFlow和CentriMag离心式血泵的机械性能比较。
Perfusion. 2010 Mar;25(2):71-6. doi: 10.1177/0267659110365366. Epub 2010 Mar 8.
6
Centrifugal pump performance during low-flow extracorporeal CO2 removal; safety considerations.
Perfusion. 2015 Jan;30(1):17-23. doi: 10.1177/0267659114540024. Epub 2014 Jun 11.
7
Optimized veno-venous bypass with the affinity pump.
ASAIO J. 2001 Jan-Feb;47(1):56-9. doi: 10.1097/00002480-200101000-00013.
8
Venous cannula performance assessment in a realistic caval tree model.在逼真的腔静脉树模型中评估静脉插管性能
Interact Cardiovasc Thorac Surg. 2015 Feb;20(2):194-9. doi: 10.1093/icvts/ivu318. Epub 2014 Nov 2.
9
Laboratory experience with a novel, non-occlusive, pressure-regulated peristaltic blood pump.
ASAIO J. 1992 Jul-Sep;38(3):M406-11. doi: 10.1097/00002480-199207000-00065.
10
Laboratory evaluation of the limitations of positive pressure safety valves on hard-shell venous reservoirs.
J Extra Corpor Technol. 2002 Jun;34(2):115-7.

引用本文的文献

1
Use of an extracorporeal circulation perfusion simulator: evaluation of its accuracy and repeatability.体外循环灌注模拟器的使用:其准确性和可重复性评估。
J Artif Organs. 2013 Dec;16(4):417-24. doi: 10.1007/s10047-013-0728-y.