• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Possible implication of sterile connecting device in contamination of pooled platelet concentrates.

作者信息

Mertens G, Muylle L, Goossens H

机构信息

Antwerp Blood Transfusion Center, Belgian Red Cross, Edegem, Belgium.

出版信息

Transfus Sci. 1997 Sep;18(3):387-92. doi: 10.1016/s0955-3886(97)00035-0.

DOI:10.1016/s0955-3886(97)00035-0
PMID:10175151
Abstract

Considering the possibility that a pooled random donor platelet concentrate could become contaminated by welding with a sterile connecting device, we undertook a study to determine the influence of pooling on the contamination rate. As a control group, apheresis platelets were examined. Bacteriological testing was done with a sensitive CO2 detecting culture system, the BacT/ Alert. Out of 1105 pooled platelet concentrates prepared by the buffy coat method, 15 (1.4%) were confirmed as contaminated, all with Staphylococcus epidermidis and two with a second bacterial species, i.e. Staphylococcus capitis and Propionibacterium acnes, respectively. Median detection time by the BacT/Alert was 23 h. Twelve pools of five units were contaminated, which is significantly more than the three contaminated pools of four units. On the other hand, the reuse of the welding wafers proved not be a risk factor for contamination. One welded tubing segment of a contaminated platelet concentrate failed the air leakage test, an incident which was 73 times more frequent than with the sterile platelet concentrates. We found five pooled platelet concentrates containing Staphylococci from which no bacteria could be grown from the individual buffy coats that had been pooled. We suggest the contamination here to have occurred after separation of the buffy coat from the whole blood, possibly during the welding process. Finally, none out of 378 apheresis platelet concentrates was contaminated. All our observations highlight the potential risk for contamination when making pooled platelet concentrates with a sterile connecting device. For this type of transfusion product, we advocate bacteriological screening of all units before release. The incubation time for the sterility test should, however, be limited to 36 h, if logistical problems with the availability of platelets are to be avoided.

摘要

相似文献

1
Possible implication of sterile connecting device in contamination of pooled platelet concentrates.
Transfus Sci. 1997 Sep;18(3):387-92. doi: 10.1016/s0955-3886(97)00035-0.
2
Bacterial contamination of platelet concentrates: results of a prospective multicenter study comparing pooled whole blood-derived platelets and apheresis platelets.血小板浓缩物的细菌污染:一项比较混合全血来源血小板和单采血小板的前瞻性多中心研究结果
Transfusion. 2007 Apr;47(4):644-52. doi: 10.1111/j.1537-2995.2007.01166.x.
3
Six years' experience of using the BacT/ALERT system to screen all platelet concentrates, and additional testing of outdated platelet concentrates to estimate the frequency of false-negative results.使用BacT/ALERT系统对所有血小板浓缩物进行筛查的六年经验,以及对过期血小板浓缩物进行额外检测以估计假阴性结果的频率。
Vox Sang. 2005 Feb;88(2):93-7. doi: 10.1111/j.1423-0410.2005.00596.x.
4
Screening of platelet concentrates for bacterial contamination: spectrum of bacteria detected, proportion of transfused units, and clinical follow-up.血小板浓缩液的细菌污染筛查:检出细菌谱、输注单位比例及临床随访。
Ann Hematol. 2010 Jan;89(1):83-91. doi: 10.1007/s00277-009-0762-2. Epub 2009 May 30.
5
Evaluation of the BacT/Alert automated blood culture system for detecting bacteria and measuring their growth kinetics in leucodepleted and non-leucodepleted platelet concentrates.评估BacT/Alert自动血培养系统在检测白细胞去除和未去除的血小板浓缩物中的细菌及其生长动力学方面的性能。
Vox Sang. 2001 Oct;81(3):154-60. doi: 10.1046/j.0042-9007.2001.00104.x.
6
Sterility of plastic tubing welds in components stored at room temperature.室温储存的部件中塑料管材焊缝的无菌性。
Transfusion. 1995 Apr;35(4):303-7. doi: 10.1046/j.1537-2995.1995.35495216078.x.
7
Monitoring of apheresis platelet bacterial contamination with an automated liquid culture system: a university experience.使用自动化液体培养系统监测单采血小板的细菌污染:一所大学的经验
Transfusion. 2003 Jul;43(7):974-8. doi: 10.1046/j.1537-2995.2003.00438.x.
8
Evaluation of the 3D BacT/ALERT automated culture system for the detection of microbial contamination of platelet concentrates.评估用于检测血小板浓缩物微生物污染的3D BacT/ALERT自动培养系统。
Transfus Med. 2002 Oct;12(5):303-9. doi: 10.1046/j.1365-3148.2002.00390.x.
9
A prospective microbiologic surveillance program to detect and prevent the transfusion of bacterially contaminated platelets.一项用于检测和预防细菌污染血小板输血的前瞻性微生物监测计划。
Transfusion. 1993 Nov-Dec;33(11):902-9. doi: 10.1046/j.1537-2995.1993.331194082380.x.
10
Use of a solid-phase fluorescent cytometric technique for the detection of bacteria in platelet concentrates.使用固相荧光细胞计数技术检测浓缩血小板中的细菌。
Transfus Med. 2005 Jun;15(3):175-83. doi: 10.1111/j.1365-3148.2005.00569.x.