A computer program modelling the formation of radiological images and predicting values of physical quantities that determine diagnostic image quality has been developed. The quantities are the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) associated with signal to noise ratio (SNR). The program is based on mathematical models that describe the effects of x-ray interactions with the imaged object and the image detector as well as phenomena concerning the optical signal propagation within the detector. All data on x-ray effects necessary for computer calculations were derived from published work whereas optical data were determined in our laboratory using experimental techniques. Model predictions were compared with direct quality measurements performed after image formation, on the image itself.
已经开发出一种计算机程序,该程序可对放射图像的形成进行建模,并预测决定诊断图像质量的物理量值。这些物理量包括调制传递函数(MTF)、噪声功率谱(NPS)以及与信噪比(SNR)相关的探测量子效率(DQE)。该程序基于数学模型,这些模型描述了X射线与成像对象和图像探测器相互作用的影响,以及探测器内光信号传播的相关现象。计算机计算所需的所有关于X射线效应的数据均来自已发表的研究成果,而光学数据则是在我们实验室使用实验技术测定的。将模型预测结果与图像形成后在图像本身上进行的直接质量测量结果进行了比较。