Suppr超能文献

超紧凑型、完全可植入的永久性使用的机电式心室辅助装置和全人工心脏。

Ultracompact, completely implantable permanent use electromechanical ventricular assist device and total artificial heart.

作者信息

Honda N, Inamoto T, Nogawa M, Takatani S

机构信息

Yamagata University, Japan.

出版信息

Artif Organs. 1999 Mar;23(3):253-61. doi: 10.1046/j.1525-1594.1999.06327.x.

Abstract

An ultracompact, completely implantable permanent use electromechanical ventricular assist device (VAD) and total artificial heart (TAH) intended for 50-60 kg size patients have been developed. The TAH and VAD share a miniature electromechanical actuator that comprises a DC brushless motor and a planetary roller screw. The rotational force of the motor is converted into the rectilinear force of the roller screw to actuate the blood pump. The TAH is a one piece design with left and right pusher plate type blood pumps sandwiching an electromechanical actuator. The VAD is one half of the TAH with the same actuator but a different pump housing and a backplate. The blood contacting surfaces, including those of the flexing diaphragm and pump housing, of both the VAD and TAH were made of biocompatible polyurethane. The diameter, thickness, volume, and weight of the VAD are 90 mm, 56 mm, 285 cc, and 380 g, respectively, while those of the TAH are 90 mm, 73 mm, 400 cc, and 440 g, respectively. The design stroke volume of both the VAD and TAH is 60 cc with the stroke length being 12 mm. The stroke length and motor speed are controlled solely based on the commutation signals of the motor. An in vitro study revealed that a maximum pump flow of 7.5 L/min can be obtained with a pump rate of 140 bpm against a mean afterload of 100 mm Hg. The power requirement ranged from 4 to 6 W to deliver a 4-5 L/min flow against a 100 mm Hg afterload with the electrical-to-hydraulic efficiency being 19-20%. Our VAD and TAH are the smallest of the currently available devices and suitable for bridge to transplant application as well as for permanent circulatory support of 50-60 kg size patients.

摘要

已研发出一种超紧凑、完全可植入的永久性使用的机电式心室辅助装置(VAD)和全人工心脏(TAH),适用于体重50至60千克的患者。TAH和VAD共用一个微型机电致动器,该致动器包括一个直流无刷电机和一个行星滚柱丝杠。电机的旋转力被转换为滚柱丝杠的直线力,以驱动血泵。TAH是一体式设计,左右推板型血泵夹着一个机电致动器。VAD是TAH的一半,具有相同的致动器,但泵壳和背板不同。VAD和TAH的血液接触表面,包括挠性隔膜和泵壳的表面,均由生物相容性聚氨酯制成。VAD的直径、厚度、体积和重量分别为90毫米、56毫米、285立方厘米和380克,而TAH的直径、厚度、体积和重量分别为90毫米、73毫米、400立方厘米和440克。VAD和TAH的设计冲程容积均为60立方厘米,冲程长度为12毫米。冲程长度和电机速度仅根据电机的换向信号进行控制。一项体外研究表明,在平均后负荷为100毫米汞柱、泵速为140次/分钟的情况下,最大泵流量可达7.5升/分钟。在100毫米汞柱后负荷下输送4至5升/分钟的流量时,功率需求范围为4至6瓦,电-液效率为19%至20%。我们的VAD和TAH是目前可用装置中最小的,适用于过渡到移植应用以及为体重50至60千克的患者提供永久性循环支持。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验