Suppr超能文献

全植入式机电一体化人工心脏的研发:贝勒人工心脏

Development of a totally implantable electromechanical total artificial heart: Baylor TAH.

作者信息

Takatani S, Shiono M, Sasaki T, Glueck J, Noon G P, Nosé Y, DeBakey M E

机构信息

Department of Surgery, Baylor College of Medicine, Houston, TX 77030, USA.

出版信息

Artif Organs. 1992 Aug;16(4):398-406. doi: 10.1111/j.1525-1594.1992.tb00539.x.

Abstract

A totally implantable, one-piece, electrome-chanical total artificial heart (TAH) intended for permanent human use has been developed. It consists of left and right pusher-plate pumps (63 cc design stroke volume) sandwiching a thin center piece with a compact electromechanical actuator. The pusher-plates are shaped conically to accommodate an actuator in the space between them. The actuator consists of an efficient and durable planetary roller screw and direct current brushless motor. The left master alternate pumping mode was implemented utilizing the left pump pusher-plate position signal. The blood-contacting surface was coated with a dry gelatin to yield long-term clot-free performance. Trileaflet tissue valves of 27 and 23 mm are used in the inflow and outflow ports. The diameter and thickness of the TAH are 97 and 82 mm. the overall volume is 510 cc, and the weight is 620 g. Anatomic fit was confirmed in 26 heart transplant recipients (body weight 78 kg and surface area 2 m2) without compressing adjacent organs. The pump performance study revealed that the TAH can yield outputs of 3-8 L/min against the 100 mm Hg afterload with 1-10 mm Hg filling pressure. The input power to the motor ranged from 7 to 12 W, with an efficiency of 18% to 14%. A one-week in vivo calf study demonstrated adequate performance of the TAH, particularly the regulation of atrial pressures. Good anatomic fit and good biocompatibility were also demonstrated.

摘要

一种完全可植入的一体式机电全人工心脏(TAH)已被研发出来,旨在供人类永久使用。它由左右推板泵(设计冲程容积为63立方厘米)夹着一个带有紧凑型机电致动器的薄中心部件组成。推板呈圆锥形,以便在它们之间的空间容纳一个致动器。该致动器由一个高效耐用的行星滚柱丝杠和直流无刷电机组成。利用左泵推板位置信号实现左主交替泵送模式。血液接触表面涂有干明胶,以实现长期无血栓性能。流入和流出端口使用27毫米和23毫米的三叶组织瓣膜。TAH的直径和厚度分别为97毫米和82毫米。总体积为510立方厘米,重量为620克。在26名心脏移植受者(体重78千克,体表面积2平方米)中证实了其解剖适应性,且不会压迫相邻器官。泵性能研究表明,TAH在1 - 10毫米汞柱的充盈压力下,能够在100毫米汞柱的后负荷下产生3 - 8升/分钟的输出。电机的输入功率范围为7至12瓦,效率为18%至14%。一项为期一周的小牛体内研究证明了TAH具有足够的性能,尤其是在调节心房压力方面。还证明了良好的解剖适应性和良好的生物相容性。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验