Bude R O, Rubin J M
Department of Radiology, University of Michigan Medical Center, Ann Arbor 48109, USA.
Radiology. 1999 May;211(2):411-7. doi: 10.1148/radiology.211.2.r99ma48411.
To evaluate the dependence of the resistive index (RI) on not only vascular resistance but also vascular compliance.
An in vitro model that made use of a pulsatile pump, blood-mimicking fluid, and variable compliance and resistance was used to investigate the relationship between the RI and both vascular compliance and resistance.
In the absence of vascular compliance, the RI was independent of vascular resistance. With vascular compliance, the RI was dependent on vascular resistance and increased with increasing resistance. The higher the compliance, the more the RI was affected by resistance.
The RI is misnamed and should actually be called the "impedance index" because resistance and compliance interact to alter the Doppler arterial waveform. A greater understanding of this relationship may enable future studies that take both resistance and compliance into account to better detect pathologic conditions.
评估阻力指数(RI)不仅对血管阻力的依赖性,还对血管顺应性的依赖性。
使用一种体外模型,该模型利用脉动泵、模拟血液的流体以及可变的顺应性和阻力,来研究RI与血管顺应性和阻力之间的关系。
在没有血管顺应性的情况下,RI与血管阻力无关。存在血管顺应性时,RI依赖于血管阻力,并随阻力增加而增加。顺应性越高,RI受阻力的影响就越大。
RI的命名有误,实际上应称为“阻抗指数”,因为阻力和顺应性相互作用会改变多普勒动脉波形。对这种关系有更深入的理解可能会使未来的研究能够同时考虑阻力和顺应性,从而更好地检测病理状况。