Suppr超能文献

Sonolysis of Albunex-supplemented, 40% hematocrit human erythrocytes by pulsed 1-MHz ultrasound: pulse number, pulse duration and exposure vessel rotation dependence.

作者信息

Brayman A A, Miller M W

机构信息

Department of Obstetrics and Gynecology, School of Medicine and Dentistry, The University of Rochester, NY 14642, USA.

出版信息

Ultrasound Med Biol. 1999 Feb;25(2):307-14. doi: 10.1016/s0301-5629(98)00157-4.

Abstract

The hypotheses tested were that sonolysis of erythrocytes in the presence of a gas-based ultrasound contrast agent in vitro will be related quantitatively to the duration and number of ultrasound pulses applied using a constant pulse repetition period and, at least qualitatively, to the total exposure duration (i.e., the product of pulse number x pulse duration). An objective was to determine the influence of sample rotation during insonation on the amount of hemolysis produced under these conditions. Human erythrocytes, suspended to 40% hematocrit in autologous plasma containing 3.6% (V:V) Albunex, were exposed/sham-exposed to 1-100 pulses of 1-MHz ultrasound (6.2 MPa peak positive, 3.6 MPa peak negative acoustic pressures; I(SPTP) approximately 800 W/cm2) using a 1-s pulse repetition period. Pulse durations ranged from 20-20,000 micros; samples were either stationary or rotated (200 rpm) during insonation. Hemolysis was independent of vessel rotation treatment at all tested pulse durations and pulse numbers. Levels of hemolysis statistically greater than in sham-exposed samples were obtained with > or = 50 pulses of 20 micros duration, and > or = 1 pulse of 200, 2000 or 20,000 micros duration. Hemolysis increased with increasing pulse number and pulse duration. Approximately equivalent levels of hemolysis were produced by different pulse number x pulse duration combinations, yielding the same total exposure duration.

摘要

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验