婴儿使用鼓膜温度计、腋温计和直肠温度计的比较。

A comparison of the use of tympanic, axillary, and rectal thermometers in infants.

作者信息

Wilshaw R, Beckstrand R, Waid D, Schaalje G B

机构信息

Utah Valley Regional Medical Center, Provo 84604, USA.

出版信息

J Pediatr Nurs. 1999 Apr;14(2):88-93. doi: 10.1016/S0882-5963(99)80042-6.

Abstract

This study examined the relationship between three instruments used in measuring tympanic, axillary, and rectal temperatures in infants less than 1 year of age. Temperatures were measured by Oto-temp Pedi Q tympanic thermometers, Becton Dickinson axillary thermometer, and rectal thermometers. A convenience sample of 5 infants less than 90 day and 54 greater than 90 days with fever, as well as 34 infants less than 90 days and 27 infants greater than 90 days without fever were studied. Correlations of infants less than 90 days and greater 90 days of age, as well as differences between infant temperature with and without fevers as variables, were examined. Results indicated a strong statistical relationship between Oto-Temp Pedi Q, Becton Dickinson axillary temperatures, and rectal temperatures, but not strong enough to base critical clinical decisions. Age and presence or absence of fever significantly affected the relationships between thermometers.

摘要

本研究探讨了用于测量1岁以下婴儿鼓膜温度、腋温及直肠温度的三种仪器之间的关系。温度分别使用耳温计Pedi Q鼓膜体温计、贝克迪金森腋温计及直肠体温计进行测量。研究选取了便利样本,包括5名90日龄以下且发烧的婴儿、54名90日龄以上且发烧的婴儿,以及34名90日龄以下未发烧的婴儿和27名90日龄以上未发烧的婴儿。研究分析了90日龄以下和90日龄以上婴儿的相关性,以及以有无发烧作为变量的婴儿体温差异。结果表明,耳温计Pedi Q、贝克迪金森腋温与直肠温度之间存在显著的统计学关系,但尚不足以据此做出关键的临床决策。年龄以及有无发烧显著影响了体温计之间的关系。