Suppr超能文献

使用亲水涂层主动脉内球囊导管减少缺血性血管并发症

Reduction in ischemic vascular complications with a hydrophilic-coated intra-aortic balloon catheter.

作者信息

Winters K J, Smith S C, Cohen M, Kopistansky C, McBride R

机构信息

Cardiovascular Division, Washington University School of Medicine, St. Louis, Missouri 63110, USA.

出版信息

Catheter Cardiovasc Interv. 1999 Mar;46(3):357-62. doi: 10.1002/(SICI)1522-726X(199903)46:3<357::AID-CCD23>3.0.CO;2-X.

Abstract

Hydrophilic coatings improve the handling characteristics of angioplasty equipment, but until recently this technology has not been available for intra-aortic balloon (IAB) catheters. To determine whether a new hydrophilic coating is associated with a reduction in IAB-related complications, we prospectively evaluated 188 patients undergoing insertion of this new IAB catheter. Complications related to IAB insertion were recorded and compared to data from 682 patients previously treated with an uncoated IAB catheter of the same shaft diameter and balloon size. By multivariate analysis the hydrophilic-coated IAB catheter was associated with a 72% reduction in ischemic vascular complications (relative risk 0.28, 95% CI 0.08-0.96, P= 0.04). There were also trends toward reductions in IAB rupture and the need for vascular surgical repair for bleeding or ischemia. While further investigation is warranted, hydrophilic coatings that reduce the coefficient of friction during IAB catheter insertion may also reduce subsequent ischemic vascular complications.

摘要

亲水性涂层改善了血管成形术设备的操作特性,但直到最近,这项技术还未应用于主动脉内球囊(IAB)导管。为了确定一种新的亲水性涂层是否与IAB相关并发症的减少有关,我们前瞻性地评估了188例接受这种新型IAB导管插入术的患者。记录与IAB插入相关的并发症,并与682例先前使用相同导管直径和球囊尺寸的未涂层IAB导管治疗的患者的数据进行比较。通过多变量分析,亲水性涂层IAB导管与缺血性血管并发症减少72%相关(相对风险0.28,95%可信区间0.08 - 0.96,P = 0.04)。IAB破裂以及因出血或缺血而需要进行血管外科修复的情况也有减少的趋势。虽然有必要进一步研究,但在IAB导管插入过程中降低摩擦系数的亲水性涂层也可能减少随后的缺血性血管并发症。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验