Eberli B, Riva C E, Feke G T
Arch Ophthalmol. 1979 Jan;97(1):145-8. doi: 10.1001/archopht.1979.01020010079018.
Mean circulation time (MCT) of sodium fluorescein in retinal vascular segments was determined in healthy human volunteers, using the dye dilution technique. The fluorescein dilution curves were recorded with a two-point fluorophotometer. Average MCT was 3.9 seconds. The accuracy of the method was determined from repeated measurements in owl monkeys and human volunteers. No significant linear correlation was found between the MCT and the cross section of the vessels feeding and those draining the segment. The application of this technique to clinical work is discussed, and is illustrated by three clinical cases.
采用染料稀释技术,在健康人类志愿者中测定了荧光素钠在视网膜血管段的平均循环时间(MCT)。用两点荧光光度计记录荧光素稀释曲线。平均MCT为3.9秒。通过对猫头鹰猴和人类志愿者的重复测量来确定该方法的准确性。未发现MCT与供血和引流该段血管的横截面积之间存在显著的线性相关性。讨论了该技术在临床工作中的应用,并通过三个临床病例进行说明。