Haqqani A S, Sandhu J K, Birnboim H C
Department of Biochemistry, Microbiology, and Immunology, University of Ottawa and the Ottawa Regional Cancer Center, Ottawa, Ontario, K1H 8L6, Canada.
Anal Biochem. 1999 Aug 15;273(1):126-32. doi: 10.1006/abio.1999.4206.
Measurement of myeloperoxidase (MPO; EC 1.11.1.7) activity is often used as a marker of neutrophil infiltration into tissues. However, most enzymatic assays for MPO are susceptible to interference from other peroxidases (including eosinophil peroxidase, EPX) and hemoproteins (such as hemoglobin and myoglobin) present in the tissues. In this report, we describe a bromide-dependent chemiluminescence (Br-CL) assay that uses luminol as a chemiluminescence probe. The assay can distinguish between MPO and nonspecific peroxidase reactions. The MPO-specific reaction is believed to proceed in two steps: (i) the enzymatic generation of hypobromous acid (HOBr) from KBr and H(2)O(2) at pH 5 and (ii) the spontaneous reaction of HOBr and H(2)O(2) with luminol to give a Br-CL signal. The assay is sufficiently sensitive to allow detection of MPO in <100 human neutrophils. Other peroxidases and hemoproteins do not interfere with the Br-CL signal. Although EPX can also oxidize bromide to generate HOBr, activities of MPO and EPX can be distinguished at different pHs. As a demonstration of the utility of the Br-CL assay, MPO activity was measured in murine tumors known to be infiltrated with neutrophils. A statistically significant correlation was seen between MPO activity and histological neutrophil counts in the tumors (r = 0.69, P < 0.01, n = 14). The assay should have wide application for measuring the neutrophil content of tissues.
髓过氧化物酶(MPO;EC 1.11.1.7)活性的测定常被用作中性粒细胞浸润组织的标志物。然而,大多数MPO的酶促测定易受组织中存在的其他过氧化物酶(包括嗜酸性粒细胞过氧化物酶,EPX)和血红素蛋白(如血红蛋白和肌红蛋白)的干扰。在本报告中,我们描述了一种使用鲁米诺作为化学发光探针的溴化物依赖性化学发光(Br-CL)测定法。该测定法可区分MPO和非特异性过氧化物酶反应。MPO特异性反应被认为分两步进行:(i)在pH 5时由KBr和H₂O₂酶促生成次溴酸(HOBr),以及(ii)HOBr和H₂O₂与鲁米诺的自发反应产生Br-CL信号。该测定法足够灵敏,能够检测不到100个人类中性粒细胞中的MPO。其他过氧化物酶和血红素蛋白不会干扰Br-CL信号。尽管EPX也能氧化溴化物生成HOBr,但MPO和EPX的活性在不同pH下可以区分。作为Br-CL测定法实用性的证明,在已知有中性粒细胞浸润的小鼠肿瘤中测量了MPO活性。在肿瘤中MPO活性与组织学中性粒细胞计数之间存在统计学上的显著相关性(r = 0.69,P < 0.01,n = 14)。该测定法在测量组织中的中性粒细胞含量方面应具有广泛的应用。