On the possibility of determining an effective energy spectrum of clinical electron beams from percentage depth dose (PDD) data of broad beams.

作者信息

Zhengming L, Jette D

机构信息

Center for Radiation Physics, INST, Sichuan University, Key Lab. for Radiation Physics and Technology of Education Ministry of China, Chengdu, People's Republic of China.

出版信息

Phys Med Biol. 1999 Aug;44(8):N177-82. doi: 10.1088/0031-9155/44/8/401.

Abstract

Experiments have already shown that obvious differences exist between the dose distribution of electron beams of a clinical accelerator in a water phantom and the dose distribution of monoenergetic electrons of nominal energy of the clinical accelerator in water, because the electron beams which reach the water surface travelling through the collimation system of the accelerator are no longer monoenergetic. It is evident that, while calculating precisely the dose distribution of any incident electron beams, the energy spectrum of the incident electron beam must be taken into consideration. In this note we shall present a method for determining an effective energy spectrum of clinical electron beams from PDD data (percentage depth dose data). It is well known that there is an integral equation of the first kind which links the energy spectrum of an incident electron beam with PDD through the dose distribution of monoenergetic electrons in the medium, as a kernel function in the integral equation. In this note, the integral equation of the first kind will be solved by using the regularization method. The bipartition model of electron transport will be used to calculate the kernel function, namely the energy deposition due to monoenergetic electron beams in the medium.

摘要

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验