Suppr超能文献

使用对比增强电子束CT获得的三维血管造影术对冠状动脉搭桥移植血管通畅性进行无创评估。

Noninvasive evaluation of coronary artery bypass graft patency using three-dimensional angiography obtained with contrast-enhanced electron beam CT.

作者信息

Ha J W, Cho S Y, Shim W H, Chung N, Jang Y, Lee H M, Choe K O, Chung W J, Choi S H, Yoo K J, Kang M S

机构信息

Cardiology Division, Yonsei Cardiovascular Center, Yonsei University College of Medicine, Seoul, Korea.

出版信息

AJR Am J Roentgenol. 1999 Apr;172(4):1055-9. doi: 10.2214/ajr.172.4.10587146.

Abstract

OBJECTIVE

The purpose of this study was to determine the accuracy of three-dimensional coronary angiography obtained with electron beam CT in the assessment of the patency of coronary artery bypass grafts.

SUBJECTS AND METHODS

Twenty-five patients who had undergone coronary artery bypass graft surgery were included. All patients underwent electron beam CT and conventional coronary angiography for the evaluation of the status of their bypass grafts. Three-dimensional reconstructions of the heart and bypass grafts were compared with selective angiographic images of the bypass grafts.

RESULTS

Fifty-seven saphenous vein grafts and 22 left internal mammary artery grafts were evaluated for occlusion or patency. Sensitivity and specificity of electron beam CT in revealing left internal mammary artery patency were 80% and 82.4%, respectively. Sensitivity and specificity of electron beam CT in revealing saphenous vein graft patency were 91.7% and 91.1%, respectively. Sensitivity and specificity of electron beam CT for evaluating saphenous vein grafts according to coronary area were as follows: saphenous vein grafts to left anterior descending artery, 100% and 100%, respectively; to diagonal branch, 100% and 100%; to left circumflex artery, 100% and 88.9%; and to right coronary artery, 75% and 85.7%.

CONCLUSION

Three-dimensional coronary angiography obtained with electron beam CT is a promising, useful, and relatively accurate diagnostic imaging technique for the evaluation of graft patency in patients who have undergone coronary artery bypass graft surgery.

摘要

目的

本研究的目的是确定电子束CT获得的三维冠状动脉造影在评估冠状动脉旁路移植术血管通畅性方面的准确性。

对象与方法

纳入25例接受冠状动脉旁路移植术的患者。所有患者均接受电子束CT和传统冠状动脉造影以评估其旁路移植血管的状况。将心脏和旁路移植血管的三维重建图像与旁路移植血管的选择性血管造影图像进行比较。

结果

共评估了57条大隐静脉移植血管和22条左乳内动脉移植血管的闭塞或通畅情况。电子束CT显示左乳内动脉通畅的敏感性和特异性分别为80%和82.4%。电子束CT显示大隐静脉移植血管通畅的敏感性和特异性分别为91.7%和91.1%。电子束CT根据冠状动脉区域评估大隐静脉移植血管的敏感性和特异性如下:至左前降支的大隐静脉移植血管,分别为100%和100%;至对角支,分别为100%和100%;至左旋支,分别为100%和88.9%;至右冠状动脉,分别为75%和85.7%。

结论

电子束CT获得的三维冠状动脉造影是一种有前景、有用且相对准确的诊断成像技术,用于评估接受冠状动脉旁路移植术患者的移植血管通畅情况。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验