Koerker D J, Goodner C J, Hansen B W, Brown A C, Rubenstein A H
Endocrinology. 1978 May;102(5):1649-52. doi: 10.1210/endo-102-5-1649.
The previously reported synchronous oscillations in plasma glucose and insulin levels have been further studied to determine whether the phenomenon can be attributed to cyclic secretion or degradation of the hormone. Plasma C-peptide concentrations were measured and found to cycle with the same period as plasma insulin suggesting that the oscillations of insulin arise from changing secretion rather than degradation. The amplitude of C-peptide oscillation was 50 percent that of insulin. Assuming first order kinetics and the same relative rates of disappearance as in humans, this difference in amplitudes in consistent with equal secretion rates for the two peptides.
先前报道的血浆葡萄糖和胰岛素水平的同步振荡已被进一步研究,以确定该现象是否可归因于激素的周期性分泌或降解。测量了血浆C肽浓度,发现其与血浆胰岛素以相同周期循环,这表明胰岛素的振荡源于分泌变化而非降解。C肽振荡的幅度是胰岛素的50%。假设为一级动力学且与人类具有相同的相对消失速率,两种肽的幅度差异与它们相等的分泌速率一致。