Suppr超能文献

肝细胞癌的血管情况:对比增强二次谐波与传统能量多普勒超声评估

Vascularity of hepatocellular carcinoma: assessment with contrast-enhanced second-harmonic versus conventional power Doppler US.

作者信息

Choi B I, Kim T K, Han J K, Kim A Y, Seong C K, Park S J

机构信息

Department of Radiology and the Institute of Radiation Medicine, Seoul National University Hospital, 28, Yongon-dong, Chongno-gu, Seoul 110-744, South Korea.

出版信息

Radiology. 2000 Feb;214(2):381-6. doi: 10.1148/radiology.214.2.r00fe01381.

Abstract

PURPOSE

To compare contrast material-enhanced harmonic power Doppler ultrasonography (US) with conventional power Doppler US in depicting the vascularity of hepatocellular carcinoma (HCC).

MATERIALS AND METHODS

Twenty patients with nodular HCCs (2.6-13.2 cm in diameter; mean diameter, 4.8 cm) were prospectively examined with both conventional and harmonic power Doppler US. US was performed with a 2-4-MHz curved linear-array transducer according to a standard examination protocol (1,000-Hz pulse repetition frequency, medium wall filter, and power gain of 55%-84% for conventional power Doppler US; 700-Hz pulse repetition frequency, low wall filter, and power gain of 95%-98% for harmonic power Doppler US). Serial, dynamic scans were obtained before intravenous injection of the contrast agent (SH U 508A) and at 30, 60, 90, 120, 180, 240, and 300 seconds after injection with both techniques.

RESULTS

The number of intratumoral power Doppler US signals was similar with both techniques at 30-90 seconds after contrast agent injection; however, after 90 seconds, conventional power Doppler US depicted significantly more signals than did harmonic power Doppler US. Harmonic power Doppler US was superior to conventional power Doppler US in terms of power Doppler artifacts such as "blooming" or motion-related artifacts.

CONCLUSION

Although the effective enhancement duration is relatively short compared with that for conventional power Doppler US, contrast-enhanced harmonic power Doppler US can be effective in evaluating the vascularity of HCCs because of the advantage of fewer power Doppler artifacts.

摘要

目的

比较对比剂增强谐波功率多普勒超声(US)与传统功率多普勒超声在显示肝细胞癌(HCC)血管方面的差异。

材料与方法

对20例患有结节性HCC(直径2.6 - 13.2 cm;平均直径4.8 cm)的患者,前瞻性地采用传统和谐波功率多普勒超声进行检查。使用2 - 4 MHz的曲线线性阵列换能器按照标准检查方案进行超声检查(传统功率多普勒超声的脉冲重复频率为1000 Hz、中等壁滤波器、功率增益为55% - 84%;谐波功率多普勒超声的脉冲重复频率为700 Hz、低壁滤波器、功率增益为95% - 98%)。在静脉注射对比剂(SH U 508A)前以及注射后30、60、90、120、180、240和300秒,用这两种技术进行连续动态扫描。

结果

在注射对比剂后30 - 90秒,两种技术显示的肿瘤内功率多普勒超声信号数量相似;然而,90秒后,传统功率多普勒超声显示的信号明显多于谐波功率多普勒超声。在诸如“开花”或运动相关伪像等功率多普勒伪像方面,谐波功率多普勒超声优于传统功率多普勒超声。

结论

尽管与传统功率多普勒超声相比,对比增强谐波功率多普勒超声的有效增强持续时间相对较短,但由于功率多普勒伪像较少的优势,其在评估HCC血管方面可能有效。