Suppr超能文献

Quality control of the isolation rate of pathogens in medical microbiology laboratories.

作者信息

Tillett H E, Crone P B

出版信息

J Hyg (Lond). 1976 Dec;77(3):359-67. doi: 10.1017/s002217240005573x.

Abstract

Two statistical analyses are suggested to compare the success rates in isolating and identifying pathogenic organisms from specimens achieved by different laboratories participating in a quality control scheme. An example is given in which the analyses are applied to 25 laboratories that received 30 simulated specimens.

摘要

相似文献

1
Quality control of the isolation rate of pathogens in medical microbiology laboratories.
J Hyg (Lond). 1976 Dec;77(3):359-67. doi: 10.1017/s002217240005573x.
2
The United Kingdom national microbiological quality assessment scheme.
J Clin Pathol. 1982 Jan;35(1):82-93. doi: 10.1136/jcp.35.1.82.
3
Quality control in microbiology. II. The need for standards.
Am J Clin Pathol. 1974 Sep;62(3):412-9. doi: 10.1093/ajcp/62.3.412.
4
Improving Gram stain proficiency in hospital and satellite laboratories that do not have microbiology.
Clin Chem Lab Med. 2017 Mar 1;55(3):458-461. doi: 10.1515/cclm-2016-0556.
5
Quality control in microbiology. I. Utilization of reference laboratory data.
Am J Clin Pathol. 1974 Sep;62(3):407-11. doi: 10.1093/ajcp/62.3.407.
6
Laboratory performance in a food microbiology proficiency testing scheme.
J Appl Bacteriol. 1992 Sep;73(3):210-16. doi: 10.1111/j.1365-2672.1992.tb02980.x.
8
Guidelines to implement quality management systems in microbiology laboratories for tissue banking.
Transplant Proc. 2009 Oct;41(8):3481-4. doi: 10.1016/j.transproceed.2009.09.012.
9
A regional quality control program in microbiology. II. Advantages of simulated clinical specimens.
Am J Clin Pathol. 1976 Aug;66(2):407-15. doi: 10.1093/ajcp/66.2.407.

引用本文的文献

本文引用的文献

1
The comparison of percentages in matched samples.
Biometrika. 1950 Dec;37(3-4):256-66.
2
Quality control in bacteriology: preliminary trials.
J Clin Pathol. 1971 Dec;24(9):790-7. doi: 10.1136/jcp.24.9.790.
3
Progress towards agreement in reports of antibiotic sensitivity.
J Clin Pathol. 1974 Dec;27(12):1001-4. doi: 10.1136/jcp.27.12.1001.
4
Quality control in diagnostic virology.
Proc R Soc Med. 1975 Oct;68(10):622-4. doi: 10.1177/003591577506801010.
5
The preparation of simulated water samples for the purpose of bacteriological quality control.
J Hyg (Lond). 1976 Feb;76(1):49-56. doi: 10.1017/s0022172400054930.