Ichikawa T, Hanawa T, Ukai H, Murakami K
University of Tokushima, School of Dentistry, Japan.
Int J Oral Maxillofac Implants. 2000 Mar-Apr;15(2):231-8.
Three-dimensional bone response to 3 biomaterials--commercially pure titanium (Ti), hydroxyapatite (HA), and calcium-ion-mixing titanium (Ca-Ti)--embedded in the tibiae of rabbits was examined chronologically. The rabbits were sacrificed at 2, 4, and 8 weeks after implantation, and the percent bone volume around each implant was calculated from the implant surface to each of 4 measurements: 36 microns, 0.25 mm, 0.5 mm, and 1.0 mm in 2 regions (cortical bone and bone marrow regions). Percent bone volume in the cortical bone was consistent, whereas in the bone marrow region, the percent bone volume varied according to implant material, implantation period, and distance from the implant surface. With Ti implants the percent increased gradually up to 8 weeks at each distance, whereas in HA and Ca-Ti implants the percent was largest at 4 weeks and increased closer to the surface. The percent with Ti implants was largest at 36 microns to 0.25 mm. Aspect of bone response to Ca-Ti was its position intermediate between those of HA and Ti. The decrease of the percent at 8 weeks was smaller than HA.
按时间顺序检查了三种生物材料——商业纯钛(Ti)、羟基磷灰石(HA)和钙离子混合钛(Ca-Ti)——植入兔胫骨后的三维骨反应。在植入后2周、4周和8周处死兔子,并计算每个植入物周围从植入物表面到四个测量点(皮质骨和骨髓区域各有36微米、0.25毫米、0.5毫米和1.0毫米)的骨体积百分比。皮质骨中的骨体积百分比是一致的,而在骨髓区域,骨体积百分比根据植入材料、植入时间和距植入物表面的距离而变化。对于Ti植入物,在每个距离处,百分比在8周时逐渐增加,而在HA和Ca-Ti植入物中,百分比在4周时最大,且越靠近表面增加越多。Ti植入物在36微米至0.25毫米处的百分比最大。骨对Ca-Ti的反应情况是其位置介于HA和Ti之间。8周时百分比的下降比HA小。