Suppr超能文献

Measurements of phase velocity and group velocity in human calcaneus.

作者信息

Wear K A

机构信息

U. S. Food and Drug Administration, Center for Devices and Radiological Health, HFZ-142, Rockville, MD 20852, USA.

出版信息

Ultrasound Med Biol. 2000 May;26(4):641-6. doi: 10.1016/s0301-5629(99)00172-6.

Abstract

Ultrasonic velocity in calcaneus correlates highly with bone mineral density, which is a good predictor of osteoporotic fracture risk. Several commercial bone sonometers perform a velocity measurement based on the transit time of a broadband pulse to assess skeletal status. This approach is somewhat problematic, however, because several authors have reported ambiguities in measurements in calcaneus. Phase velocity is an alternative that may be less dependent on device spectral characteristics. In addition, dispersion (the frequency-dependence of phase velocity) is a fundamental property worth investigating to increase understanding of interaction between ultrasound and bone. To compare two group-velocity measurement methods and one phase-velocity measurement method, a polycarbonate sample (for method validation) and 24 human calcanei were investigated in vitro. Phase velocity in calcaneus at 500 kHz was 1511 m/s +/- 30 m/s (mean +/- standard deviation). Average phase velocity decreased approximately linearly with frequency (-18 m/s MHz). The two group velocity measurements were comparable and tended to be slightly lower than phase velocity. The magnitude of dispersion showed little correlation with bone mineral density.

摘要

相似文献

1
Measurements of phase velocity and group velocity in human calcaneus.
Ultrasound Med Biol. 2000 May;26(4):641-6. doi: 10.1016/s0301-5629(99)00172-6.
2
Measurements of acoustic dispersion on calcaneus using spilt spectrum processing technique.
Med Eng Phys. 2006 Mar;28(2):187-93. doi: 10.1016/j.medengphy.2005.04.018. Epub 2005 Jun 6.
3
Frequency dependence of average phase shift from human calcaneus in vitro.
J Acoust Soc Am. 2009 Dec;126(6):3291-300. doi: 10.1121/1.3257550.
4
Group velocity, phase velocity, and dispersion in human calcaneus in vivo.
J Acoust Soc Am. 2007 Apr;121(4):2431-7. doi: 10.1121/1.2697436.
6
A stratified model to predict dispersion in trabecular bone.
IEEE Trans Ultrason Ferroelectr Freq Control. 2001 Jul;48(4):1079-83. doi: 10.1109/58.935726.
7
Evaluation of a gel-coupled quantitative ultrasound device for bone status assessment.
J Ultrasound Med. 2001 Nov;20(11):1219-28. doi: 10.7863/jum.2001.20.11.1219.

引用本文的文献

1
Scattering in Cancellous Bone.
Adv Exp Med Biol. 2022;1364:163-175. doi: 10.1007/978-3-030-91979-5_8.
2
Tissue-mimicking phantoms for performance evaluation of photoacoustic microscopy systems.
Biomed Opt Express. 2022 Feb 7;13(3):1357-1373. doi: 10.1364/BOE.445702. eCollection 2022 Mar 1.
3
Spatio-Spectral Ultrasound Characterization of Reflection and Transmission Through Bone With Temperature Dependence.
IEEE Trans Ultrason Ferroelectr Freq Control. 2022 May;69(5):1727-1737. doi: 10.1109/TUFFC.2022.3163225. Epub 2022 Apr 27.
4
Polyacrylamide hydrogel phantoms for performance evaluation of multispectral photoacoustic imaging systems.
Photoacoustics. 2021 Feb 20;22:100245. doi: 10.1016/j.pacs.2021.100245. eCollection 2021 Jun.
5
Mechanisms of Interaction of Ultrasound With Cancellous Bone: A Review.
IEEE Trans Ultrason Ferroelectr Freq Control. 2020 Mar;67(3):454-482. doi: 10.1109/TUFFC.2019.2947755. Epub 2019 Oct 16.
6
Relationships among ultrasonic and mechanical properties of cancellous bone in human calcaneus in vitro.
Bone. 2017 Oct;103:93-101. doi: 10.1016/j.bone.2017.06.021. Epub 2017 Jun 27.
7
Biologically relevant photoacoustic imaging phantoms with tunable optical and acoustic properties.
J Biomed Opt. 2016 Oct;21(10):101405. doi: 10.1117/1.JBO.21.10.101405.

本文引用的文献

1
Velocity dispersion of acoustic waves in cancellous bone.
IEEE Trans Ultrason Ferroelectr Freq Control. 1998;45(3):581-92. doi: 10.1109/58.677603.
2
The effects of frequency-dependent attenuation and dispersion on sound speed measurements: applications in human trabecular bone.
IEEE Trans Ultrason Ferroelectr Freq Control. 2000;47(1):265-73. doi: 10.1109/58.818770.
4
Ultrasound velocity of trabecular cubes reflects mainly bone density and elasticity.
Calcif Tissue Int. 1999 Jan;64(1):18-23. doi: 10.1007/s002239900572.
7
The effect of cortical endplates on ultrasound velocity through the calcaneus: an in vitro study.
Br J Radiol. 1997 May;70(833):504-10. doi: 10.1259/bjr.70.833.9227233.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验