Smith M S, Dyson R J, Hale T, Janaway L
Centre for Sports Science, University College Chichester, UK.
J Sports Sci. 2000 Jun;18(6):445-50. doi: 10.1080/02640410050074377.
The development of sport-specific dynamometers is an important step towards ecological validity in analysing athlete performance. Design limitations in previous punch-measuring devices have resulted in values which may not or cannot fully reflect the force and multidirectional components in a punch. In developing this boxing dynamometer, a triaxial force measurement system and a boxing manikin interface were combined. The repeatability and accuracy of the dynamomoter were assessed using simulated straight punches. Discrimination efficacy was assessed by comparison of the maximal punching force of seven elite, eight intermediate and eight novice boxers during simulated boxing, throwing straight punches. For the elite, intermediate and novice groups, respectively, the maximal straight punching forces (mean +/- s(mean)) were 4800 +/- 227 N, 3722 +/- 133 N and 2381 +/- 116 N for the rear hand, and 2847 +/- 225 N, 2283 +/- 126 N and 1604 +/- 97 N for the lead hand. For all groups, maximal forces were larger for the rear than the lead hand (P < 0.001). Maximal punching force was greater in the elite than the intermediate group, and greater in the intermediate than the novice group (P < 0.05). The boxing dynamometer discriminated effectively between punching performance at three standards of performance and between the punching force of the rear and lead hands.
开发特定运动的测力计是在分析运动员表现时提高生态效度的重要一步。以往拳击测力装置的设计局限性导致其测量值可能无法或不能完全反映拳击时的力量和多方向分量。在开发这款拳击测力计时,将三轴力测量系统与拳击人体模型接口相结合。使用模拟直拳评估了测力计的重复性和准确性。通过比较七名精英拳击手、八名中级拳击手和八名新手拳击手在模拟拳击直拳时的最大拳击力来评估辨别效能。对于精英组、中级组和新手组,后手的最大直拳力(平均值±标准误)分别为4800±227N、3722±133N和2381±116N,前手分别为2847±225N、2283±126N和1604±97N。对于所有组,后手的最大力量均大于前手(P<0.001)。精英组的最大拳击力大于中级组,中级组大于新手组(P<0.05)。该拳击测力计能够有效区分三种表现水平的拳击表现以及后手和前手的拳击力。