Lesesve J F, Haristoy X, Thouvenin M, Latger-Cannard V, Buisine J, Lecompte T
Laboratoire d'hématologie, CHU Brabois, 54511 Vandoeuvre-lès-Nancy.
Ann Biol Clin (Paris). 2000 Jul-Aug;58(4):417-24.
Leukoagglutination is a rare EDTA-dependent phenomenon resulting in a spurious minoration of the leukocyte count performed using automated analyzers. We described seven cases. The leukocyte agglutination was detected by unstable WBC count, abnormal WBC histograms and presence of clusters of polymorphonuclears on the smear. PMN aggregates of 3 to 10 cells or bigger were observed. Discrepancies between the erroneous automated WBC count and the real count were moderate in most cases. Leukoagglutination was related to lymphoproliferative disorders, infections, alcoholic liver diseases, auto-immune diseases. Inflammatory context seemed to be requested. For few patients, the artefact occurred regardless of the type of anticoagulants (lithium heparin, buffered sodium citrate) and warming at 37 C did not always increase the WBC. Dilution in Unopette chambers was required. We confirmed that leukoagglutination of PMN was an in vitro artefact EDTA and/or temperature mediated.
白细胞凝集是一种罕见的依赖乙二胺四乙酸(EDTA)的现象,会导致使用自动分析仪进行的白细胞计数出现假性减少。我们描述了7例病例。通过不稳定的白细胞计数、异常的白细胞直方图以及涂片上多形核白细胞簇的存在来检测白细胞凝集。观察到3至10个细胞或更大的多形核白细胞聚集体。在大多数情况下,错误的自动白细胞计数与实际计数之间的差异适中。白细胞凝集与淋巴增殖性疾病、感染、酒精性肝病、自身免疫性疾病有关。似乎需要炎症背景。对于少数患者,无论使用何种抗凝剂(锂肝素、枸橼酸钠缓冲液)都会出现这种假象,并且在37℃加热并不总是能增加白细胞数量。需要在尤诺佩特计数池(Unopette chambers)中进行稀释。我们证实,多形核白细胞的白细胞凝集是一种由EDTA和/或温度介导的体外假象。