• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Adequacy in hemodialysis: new concepts derived from online urea monitoring.

作者信息

Arrigo G, Beltrame A, Colasanti G

机构信息

Division of Nephrology and Dialysis, San Carlo Hospital, Milan, Italy.

出版信息

Kidney Int Suppl. 2000 Aug;76:S41-6. doi: 10.1046/j.1523-1755.2000.07605.x.

DOI:10.1046/j.1523-1755.2000.07605.x
PMID:10936798
Abstract

BACKGROUND

The estimation of urea kinetic parameters [urea generation rate (Gu), normalized protein catabolic rate (NPCR), and dialysis dose (Kt/V)] is routinely performed during a single hemodialysis session as a representative sample of a stable series. To ascertain whether the stability assumption is tenable and to estimate the variability of urea kinetic parameters, a number of stable patients on regular dialysis treatment in their usual clinical setting were followed.

METHODS

Thirteen stable patients on regular hemodialysis aged 61 +/- 11 were monitored from 5 to 24 weeks (median, 10 weeks) with the urea biosensor system in double-chamber hemodiafiltration. Body weight did not change appreciably. Residual renal function was negligible or absent. Weekly averaged urea concentration (TACw), Gu, NPCR, and Kt/Veq were calculated, and their serial patterns and interrelationships were evaluated through graphical analysis and linear regression.

RESULTS

In six patients, the urea pool was substantially unchanged, but variability of Gu and Kt/V was comparable to that of the other groups. In three patients, body urea pool increased. Gu went from 4. 78 +/- 0.44 to 5.40 +/- 0.65 mg/min, and Kt/V went from 1.25 +/- 0. 25 to 1.34 +/- 0.31. In four patients, body urea pool decreased; Gu went from to 6.55 +/- 1.91 to 5.85 +/- 2.26 mg/min, and Kt/V did not change appreciably. Parameters might change in a nearly linear trend or occasionally as abrupt or oscillating phases. Gu was the main factor involved, and the only one affecting four of the seven unstable patients. Kt/V was never solely involved.

CONCLUSIONS

Our data indicate that the estimation of urea kinetic parameters is often affected by a non-negligible degree of variability, which can be ascribed to the variability of the dialytic dose delivered and, above all, to the daily changes of diet protein assumption.

摘要

相似文献

1
Adequacy in hemodialysis: new concepts derived from online urea monitoring.
Kidney Int Suppl. 2000 Aug;76:S41-6. doi: 10.1046/j.1523-1755.2000.07605.x.
2
Urea as a marker of adequacy in hemodialysis: lesson from in vivo urea dynamics monitoring.尿素作为血液透析充分性的标志物:来自体内尿素动力学监测的经验教训。
Kidney Int Suppl. 2000 Aug;76:S28-40. doi: 10.1046/j.1523-1755.2000.07604.x.
3
Evaluation of high-flux hemodiafiltration efficiency using an on-line urea monitor.使用在线尿素监测仪评估高通量血液透析滤过效率
Am J Kidney Dis. 1998 Jan;31(1):74-80. doi: 10.1053/ajkd.1998.v31.pm9428455.
4
Routine Kt/V and Normalized Protein Nitrogen Appearance Rate Determined From Conductivity Access Clearance With Infrequent Postdialysis Serum Urea Nitrogen Measurements.利用电导测定法获得的频繁血透后尿素氮测量的通透性清除率估算常规 Kt/V 和标准化蛋白分解率。
Am J Kidney Dis. 2020 Jul;76(1):22-31. doi: 10.1053/j.ajkd.2019.12.007. Epub 2020 Mar 24.
5
[Evaluation of methods to calculate dialysis dose in daily hemodialysis].[每日血液透析中透析剂量计算方法的评估]
Nefrologia. 2003 Jul-Aug;23(4):344-9.
6
Effects of postdialysis urea rebound on the quantification of pediatric hemodialysis.透析后尿素反弹对小儿血液透析定量的影响。
Nephron. 2000 Feb;84(2):124-9. doi: 10.1159/000045559.
7
Assessing dialysis adequacy and dietary intake in the individual hemodialysis patient.评估个体血液透析患者的透析充分性和饮食摄入量。
Kidney Int. 1999 May;55(5):1961-9. doi: 10.1046/j.1523-1755.1999.00412.x.
8
On-line assessment of delivered dialysis dose.透析剂量输送的在线评估。
Kidney Int. 1998 Jul;54(1):263-7. doi: 10.1046/j.1523-1755.1998.00979.x.
9
Evaluation of pre- and postdilutional on-line hemodiafiltration adequacy by partial dialysate quantification and on-line urea monitor.通过部分透析液定量和在线尿素监测评估预稀释和后稀释在线血液透析滤过的充分性。
Blood Purif. 1999;17(4):199-205. doi: 10.1159/000014396.
10
Assessment of the length of each hemodialysis session by on-line dialysate urea monitoring.通过在线透析液尿素监测评估每次血液透析治疗的时长。
Nephron. 2001 Sep;89(1):37-42. doi: 10.1159/000046041.

引用本文的文献

1
Ensuring hemodialysis adequacy by dialysis dose monitoring with UV spectroscopy analysis of spent dialyzate.通过对废弃透析液进行紫外线光谱分析的透析剂量监测来确保血液透析充分性。
Int J Artif Organs. 2022 Apr;45(4):351-359. doi: 10.1177/03913988211059841. Epub 2021 Nov 23.