Aymard G, Labarthe B, Warot D, Berlin I, Diquet B
Laboratoire de Pharmacocinétique, Centre Hospitalier et Universitaire de la Pitié-Salpétrière, Paris, France.
J Chromatogr B Biomed Sci Appl. 2000 Jul 7;744(1):25-31. doi: 10.1016/s0378-4347(00)00217-6.
A high-performance liquid chromatography procedure for the determination of ephedrine and norephedrine using fluorimetric detection in plasma samples is described. A double liquid-liquid extraction was performed, followed by derivatization with 9-fluorenylmethyl chloroformate. The extracts were chromatographed with a 5-microm C18 (150x4.6 mm I.D.) column using a mobile phase composed of acetonitrile and water (52:48; v/v). The excitation and emission wavelengths were respectively 264 nm and 313 nm. Calibration curves were linear over the range 0 to 300 ng/ml for each analyte. The specificity of the method was demonstrated with several FMOC-reacting drugs. The limits of quantification are similar to those obtained with the reference method: 2 ng/ml for ephedrine and 5 ng/ml for norephedrine. This method has been successfully applied to the determination of ephedrine and norephedrine plasma levels after administration of low doses of ephedrine to healthy subjects.