Abstract

Some syphilitic sera still fluoresce with Reiter treponemes as the antigen after treatment with the sorbent used in the FTA-ABS test; this finding indicates incomplete removal of group antitreponemal antibody. Levels of this antibody in normal sera have been studied in relation to the titration of sorbent for use in the test. A comparison has been made of the results of FTA-ABS tests with sorbent and Reiter sonicate and the TPI test on 1141 selected problem sera. Results with the sonicate displayed closer agreement (60.9%) with those of the TPI test than did tests with sorbent 40.8%). The use of sonicate as the sorbing agent is thought to improve the performance of the FTA-ABS test without diminishing its sensitivity.

摘要

一些梅毒血清在用FTA-ABS试验中使用的吸附剂处理后,以Reiter密螺旋体作为抗原仍会产生荧光;这一发现表明抗密螺旋体抗体组未被完全清除。已针对该试验中使用的吸附剂滴定研究了正常血清中这种抗体的水平。对1141份选定的疑难血清进行了FTA-ABS试验(使用吸附剂和Reiter超声裂解物)和TPI试验的结果比较。与使用吸附剂的试验(40.8%)相比,超声裂解物的试验结果与TPI试验的结果显示出更密切的一致性(60.9%)。使用超声裂解物作为吸附剂被认为可以提高FTA-ABS试验的性能而不降低其灵敏度。