Al-Qudah A A, Mostratos A
J Med Microbiol. 1984 Jun;17(3):273-82. doi: 10.1099/00222615-17-3-273.
A single radial haemolysis (SRH) technique, using Reiter protein or Reiter lysate as the coating antigen, was investigated. Results obtained with syphilitic and presumed non-syphilitic human sera were compared with results obtained in the absorbed fluorescent treponemal antibody test (FTA-ABS), the Reiter protein complement fixation test ( RPCFT ), the Venereal Diseases Research Laboratory Slide test (VDRL) and the Cardiolipin Wasserman reaction ( CWR ). The SRH reaction, with either Reiter antigen, was more sensitive than any of the screening tests ( RPCFT , VDRL and CWR ) for detecting positive syphilitic antibodies. Although the SRH test used almost the same materials as the RPCFT , it was appreciably more sensitive for the detection of the group-specific antibodies in syphilitic human serum.
研究了一种使用赖特蛋白或赖特裂解物作为包被抗原的单径向溶血(SRH)技术。将梅毒患者和疑似非梅毒患者血清的检测结果与吸附荧光密螺旋体抗体试验(FTA-ABS)、赖特蛋白补体结合试验(RPCFT)、性病研究实验室玻片试验(VDRL)和心磷脂瓦色曼反应(CWR)的结果进行了比较。使用任一赖特抗原的SRH反应在检测梅毒阳性抗体方面比任何一种筛查试验(RPCFT、VDRL和CWR)都更敏感。虽然SRH试验使用的材料与RPCFT几乎相同,但在检测梅毒患者血清中的群特异性抗体方面明显更敏感。