Savage M O, Hibble A G, Pickering D
Arch Dis Child. 1975 May;50(5):393-5. doi: 10.1136/adc.50.5.393.
We have measured the plasma concentrations in sick neonates and infants being administered digoxin by a safer regimen. In the presence of normal renal function the plasma concentrations appear to be satisfactory.
我们已经测量了采用更安全给药方案的患病新生儿和婴儿的地高辛血药浓度。在肾功能正常的情况下,血药浓度似乎是令人满意的。