Laine H J, Puolakka T J, Moilanen T, Pajamäki K J, Wirta J, Lehto M U
Department of Surgery, Medical School, University of Tampere, and Tampere University Hospital, Finland.
Int Orthop. 2000;24(4):184-90. doi: 10.1007/s002640000150.
We measured the post-operative radiological "fit and fill" of two different femoral stem designs, one with a straight proximally porous-coated (Bi-Metric, n=50) and the other with a proximally anatomic, hydroxyapatite-coated and distally over-reamed stem (ABG, n=26). A comparison was then made between the clinical and radiological 5-year follow-up data of these two series and also of the bone remodeling changes around the stems. The observed differences in "fit and fill" parameters in the metaphyseal region were minute. However, in the diaphyseal bone the straight stem had substantially more cortical contact. The clinical results were excellent for both groups. Subsidence (>2 mm) was more frequent with the anatomical ABG stems, although the ABG stems had better bone ingrowth in the lower metaphyseal area. The present results indicate that the anatomical design may improve the fit and fill of a femoral stem in the metaphysis. On the other hand, a looser fill of the diaphyseal bone made the stems of this type more susceptible to subsidence. The straight stem with tight diaphyseal fit showed excellent stability, but the good bone ingrowth and remodeling around the distal part of the stem indicates stress transfer through this region and increased stress shielding of the proximal metaphyseal femur.
我们测量了两种不同股骨柄设计的术后影像学“贴合与填充”情况,一种是近端多孔涂层的直柄(双度量型,n = 50),另一种是近端解剖型、羟基磷灰石涂层且远端扩髓的柄(ABG型,n = 26)。然后对这两个系列的临床和影像学5年随访数据以及柄周围的骨重塑变化进行了比较。在干骺端区域观察到的“贴合与填充”参数差异微小。然而,在骨干骨中,直柄的皮质接触明显更多。两组的临床结果都很出色。解剖型ABG柄下沉(>2 mm)更为常见,尽管ABG柄在干骺端下部区域的骨长入情况更好。目前的结果表明,解剖型设计可能会改善股骨柄在干骺端的贴合与填充。另一方面,骨干骨填充较松使这种类型的柄更容易下沉。干骺端紧密贴合的直柄显示出出色的稳定性,但柄远端周围良好的骨长入和重塑表明应力通过该区域传递,近端干骺端股骨的应力遮挡增加。