Suppr超能文献

非骨水泥型股骨柄形状和近端表面纹理对“匹配与填充”特性及骨重塑的影响。

The effects of cementless femoral stem shape and proximal surface texture on 'fit-and-fill' characteristics and on bone remodeling.

作者信息

Laine H J, Puolakka T J, Moilanen T, Pajamäki K J, Wirta J, Lehto M U

机构信息

Department of Surgery, Medical School, University of Tampere, and Tampere University Hospital, Finland.

出版信息

Int Orthop. 2000;24(4):184-90. doi: 10.1007/s002640000150.

Abstract

We measured the post-operative radiological "fit and fill" of two different femoral stem designs, one with a straight proximally porous-coated (Bi-Metric, n=50) and the other with a proximally anatomic, hydroxyapatite-coated and distally over-reamed stem (ABG, n=26). A comparison was then made between the clinical and radiological 5-year follow-up data of these two series and also of the bone remodeling changes around the stems. The observed differences in "fit and fill" parameters in the metaphyseal region were minute. However, in the diaphyseal bone the straight stem had substantially more cortical contact. The clinical results were excellent for both groups. Subsidence (>2 mm) was more frequent with the anatomical ABG stems, although the ABG stems had better bone ingrowth in the lower metaphyseal area. The present results indicate that the anatomical design may improve the fit and fill of a femoral stem in the metaphysis. On the other hand, a looser fill of the diaphyseal bone made the stems of this type more susceptible to subsidence. The straight stem with tight diaphyseal fit showed excellent stability, but the good bone ingrowth and remodeling around the distal part of the stem indicates stress transfer through this region and increased stress shielding of the proximal metaphyseal femur.

摘要

我们测量了两种不同股骨柄设计的术后影像学“贴合与填充”情况,一种是近端多孔涂层的直柄(双度量型,n = 50),另一种是近端解剖型、羟基磷灰石涂层且远端扩髓的柄(ABG型,n = 26)。然后对这两个系列的临床和影像学5年随访数据以及柄周围的骨重塑变化进行了比较。在干骺端区域观察到的“贴合与填充”参数差异微小。然而,在骨干骨中,直柄的皮质接触明显更多。两组的临床结果都很出色。解剖型ABG柄下沉(>2 mm)更为常见,尽管ABG柄在干骺端下部区域的骨长入情况更好。目前的结果表明,解剖型设计可能会改善股骨柄在干骺端的贴合与填充。另一方面,骨干骨填充较松使这种类型的柄更容易下沉。干骺端紧密贴合的直柄显示出出色的稳定性,但柄远端周围良好的骨长入和重塑表明应力通过该区域传递,近端干骺端股骨的应力遮挡增加。

相似文献

3
Femoral fit in ABG-II hip stems, influence on clinical outcome and bone remodeling: a radiographic study.
Arch Orthop Trauma Surg. 2008 Oct;128(10):1065-72. doi: 10.1007/s00402-007-0537-y. Epub 2007 Dec 6.
5
Cementless Tapered Wedge Femoral Stems Decrease Subsidence in Obese Patients Compared to Traditional Fit-and-Fill Stems.
J Arthroplasty. 2017 Mar;32(3):891-897. doi: 10.1016/j.arth.2016.09.023. Epub 2016 Sep 28.
6
Bone remodeling is different in metaphyseal and diaphyseal-fit uncemented hip stems.
Clin Orthop Relat Res. 2006 Oct;451:128-33. doi: 10.1097/01.blo.0000224045.63754.a3.
7
Porous Femoral Fixation in Total Hip Arthroplasty with Short Anatomical Stem: Radiographic Evaluation.
Clin Orthop Surg. 2017 Sep;9(3):255-262. doi: 10.4055/cios.2017.9.3.255. Epub 2017 Aug 4.
9
Subsidence of Hydroxyapatite-Coated Femoral Stem in Dorr Type C Proximal Femoral Morphology.
J Arthroplasty. 2019 Sep;34(9):2011-2015. doi: 10.1016/j.arth.2019.05.017. Epub 2019 May 15.

引用本文的文献

3
4
6
Radiological Evaluation of the Relationship Between Cortical Hypertrophy and Stress Shielding After Total Hip Arthroplasty Using a Cementless Stem.
Arthroplast Today. 2020 Nov 3;6(4):894-900. doi: 10.1016/j.artd.2020.09.018. eCollection 2020 Dec.
8
Reconsideration of the Effects of Age on Proximal Femur Structure: Implications for Joint Replacement and Hip Fracture.
PLoS One. 2016 Oct 24;11(10):e0164949. doi: 10.1371/journal.pone.0164949. eCollection 2016.
10
Surgical treatment options in patients with impaired bone quality.
Clin Orthop Relat Res. 2011 Aug;469(8):2237-47. doi: 10.1007/s11999-011-1838-6.