Rainey Joshua, Frandsen Jeffrey, Mortensen Alexander, Faizan Ahmad, Bhowmik-Stoker Manoshi, Springer Bryan, Gililland Jeremy
Department of Orthopaedic Surgery, University of Utah, Salt Lake City, UT, USA.
Stryker Orthopaedics, Mahwah, NJ, USA.
Arthroplast Today. 2023 Sep 19;23:101199. doi: 10.1016/j.artd.2023.101199. eCollection 2023 Oct.
Numerous cementless stems are available to maximize implant stability, fit, and survivorship in total hip arthroplasty. Recently, a new metaphyseal-filling triple-taper collared stem was designed using femoral morphology data obtained from over 1300 computed tomography scans. The purpose of this study was to evaluate the radiographic fit and fill of this new stem in the coronal and sagittal dimensions.
In this retrospective review, postoperative radiographs of patients receiving this new stem were analyzed in accordance with previously published fit and fill analyses. All radiographs were taken 6 weeks postoperatively. Means and standard deviations were reported for all fit and fill parameters.
Fifty-nine hips were analyzed from 55 patients undergoing total hip arthroplasty. The coronal proximal fill was 85.02 ± 8.06%, and coronal distal fill was 75.21 ± 9.71%. The sagittal proximal fill was 86.51 ± 8.77%, and sagittal distal fill was 59.17 ± 8.66%. Mean calcar collar coverage was 80.64 ± 19.6% and all patients had full seating of the collar. Six cases (10.2%) had a collar length greater than the calcar length, with a mean collar overhang of 0.7 ± 0.4 mm.
This new stem demonstrated significant proximal fill in both the coronal and sagittal planes and validates the design intent of this implant. This is the first study to evaluate sagittal fit and fill of a femoral stem. Long-term follow-up is required to understand the clinical impact these fit and fill characteristics may have on patients' long-term outcomes.
在全髋关节置换术中,有多种非骨水泥型股骨柄可供选择,以实现植入物的稳定性、适配性和长期生存率最大化。最近,利用从1300多例计算机断层扫描获得的股骨形态数据,设计了一种新型的干骺端填充三锥领股骨柄。本研究的目的是评估这种新型股骨柄在冠状面和矢状面的影像学适配性和填充情况。
在这项回顾性研究中,根据先前发表的适配性和填充分析方法,对接受这种新型股骨柄的患者术后X线片进行分析。所有X线片均在术后6周拍摄。报告所有适配性和填充参数的均值及标准差。
对55例行全髋关节置换术患者的59髋进行了分析。冠状面近端填充率为85.02±8.06%,冠状面远端填充率为75.21±9.71%。矢状面近端填充率为86.51±8.77%,矢状面远端填充率为59.17±8.66%。平均股骨距领覆盖率为80.64±19.6%,所有患者的领均完全就位。6例(10.2%)患者的领长度大于股骨距长度,平均领悬出为0.7±0.4mm。
这种新型股骨柄在冠状面和矢状面均显示出显著的近端填充,验证了该植入物的设计意图。这是第一项评估股骨干矢状面适配性和填充情况的研究。需要进行长期随访,以了解这些适配性和填充特征对患者长期预后的临床影响。