Suppr超能文献

Transvenous left ventricular lead implantation with the EASYTRAK lead system: the European experience.

作者信息

Pürerfellner H, Nesser H J, Winter S, Schwierz T, Hörnell H, Maertens S

机构信息

Department of Cardiology, Elisabethinen Hospital, Linz, Austria.

出版信息

Am J Cardiol. 2000 Nov 2;86(9A):157K-164K. doi: 10.1016/s0002-9149(00)01299-6.

Abstract

Several independent studies suggest that resynchronization therapy--achieved by left- or biventricular pacing--improves hemodynamics in heart failure patients with interventricular conduction disturbances. Delivery of this new therapy in an effective and minimally invasive manner presents technical challenges, as transvenous access to the left ventricle is required. Since 1999, a novel over-the-wire approach combining standard pacing lead and angioplasty technology has been evaluated in several European countries. This new left ventricular lead, the EASYTRAK system (Guidant, St. Paul, MN), has been clinically evaluated in 2 phases. The first phase was a clinical investigation to obtain the CE-mark (i.e. European Commission approval). The second phase, which started immediately after the CE-mark was obtained, consisted of a postmarket surveillance called the European registry. This article reports on the results of the pre-CE-mark clinical investigation and the preliminary results of the European registry (first 150 patients). During the pre-CE-mark clinical investigation of the EASYTRAK system, lead performance was assessed in 36 successfully implanted patients. The patients had indications for VVI-pacing, symptoms of heart failure and significant left ventricular dysfunction. The left ventricular lead was implanted in conjunction with a conventional right ventricular lead and a new heart failure device (CONTAK TR, Guidant, Brussels, Belgium). Lead measurements (threshold, sensing, and impedance) were performed at implant and subsequent follow-ups. The stimulation thresholds at 0.5 msec impulse width were acceptable, although (as expected) slightly higher than with standard right ventricular pacing leads: 1.39 +/- 1.15 V at implant, 1.72 +/- 1.26 V at predischarge, 1.54 +/- 0.88 V at 2 weeks, 1.38 +/- 0.80 V at 6 weeks, and 1.24 +/- 0.73 V at 12 weeks. R-wave and impedance measurements were stable over time. A revision of the EASYTRAK lead was required in 3 patients. No perforations were observed. During the second phase of the European registry, 150 implants were attempted in 63 centers from November 1999 to January 2000. The EASYTRAK was implanted with a pulse generator offering, in addition to resynchronization therapy, either tachycardia monitoring (CONTAK TR) or implantable cardioverter defibrillator therapy (CONTAK CD), depending on the patient indication. Over half of the centers involved had not previously implanted the EASYTRAK system. Total implant success rate was 83% (135/150), skin-to-skin duration of the implant was 169 +/- 81 minutes (range, 53-480 minutes), with a clear learning curve. Once the coronary sinus was found, the implant success rate was 92%. One lead dislodgment and 2 cases of phrenic nerve stimulation were reported. We conclude that the new EASYTRAK lead design for transvenous left ventricular lead implantation seems to be a suitable and safe tool for delivering resynchronization therapy to heart failure patients.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验