Suppr超能文献

评估琼斯矫治器对远中磨牙移动的作用。

Evaluation of the Jones jig appliance for distal molar movement.

作者信息

Brickman C D, Sinha P K, Nanda R S

机构信息

University of Oklahoma, College of Dentistry, Department of Orthodontics, Oklahoma City, USA.

出版信息

Am J Orthod Dentofacial Orthop. 2000 Nov;118(5):526-34. doi: 10.1067/mod.2000.110332.

Abstract

The purpose of this study was to determine the effects of the Jones jig appliance on distal movement of maxillary molars and reciprocal effects on premolars and maxillary incisors. Cephalometric radiographs before and after orthodontic treatment of 72 consecutively treated patients, 46 females and 26 males, were measured to define treatment changes attributed to the Jones jig. Comparative measurements were made on a matched sample of 35 patients (20 females and 15 males) treated with cervical headgear by the same clinician. Both series of patients were treated to correct an Angle Class II molar relationship. The molar correction in the Jones jig patients consisted primarily of molar distal movement. Dental, soft tissue, and skeletal changes were evaluated and compared for significant differences between techniques. The results from the Jones jig sample showed the mean maxillary first molar distal movement was 2.51 mm, with distal tipping of 7.53 degrees. The mean reciprocal mesial movement of the maxillary premolar was 2.0 mm, with mesial tipping of 4.76 degrees. The maxillary first molar extruded 0.14 mm; the maxillary premolar extruded 1.88 mm. The maxillary second molars were also moved distally 2.02 mm and tipped distally 7.89 degrees. The longitudinal assessment (initial to completion of orthodontic treatment) showed significant differences between the Jones jig sample and the cervical headgear sample for lower lip to E-line and SNA. The Jones jig sample showed a mean decrease in lower lip to E-line of 0.25 mm versus 1.20 mm (P < .0212) for the headgear sample. SNA decreased 0.40 degrees for the Jones jig sample versus 1.20 degrees (P < .0093) for the headgear sample. However, the Jones jig sample and cervical headgear sample did not show significant differences of the final position in either linear or angular measurements of the maxillary first molars and corresponding premolar-incisor anchor units. The Jones jig appliance demonstrated treatment results comparable with those of the sample treated with cervical headgear. The Jones jig sample demonstrated effective distal molar movement and maintenance of the Class I molar relationship. Advantages of the Jones jig include minimal dependence on patient compliance, ease of fabrication, and ease of buccal force application.

摘要

本研究的目的是确定琼斯矫治器对上颌磨牙远中移动的影响以及对前磨牙和上颌切牙的交互作用。对72例连续接受治疗的患者(46例女性和26例男性)正畸治疗前后的头影测量X线片进行测量,以确定归因于琼斯矫治器的治疗变化。对由同一位临床医生用颈带矫治器治疗的35例患者(20例女性和15例男性)的匹配样本进行了对比测量。两组患者均接受治疗以纠正安氏II类磨牙关系。琼斯矫治器组患者的磨牙矫正主要包括磨牙远中移动。对牙齿、软组织和骨骼变化进行了评估,并比较了两种技术之间的显著差异。琼斯矫治器样本的结果显示,上颌第一磨牙平均远中移动2.51mm,远中倾斜7.53度。上颌前磨牙平均近中交互移动2.0mm,近中倾斜4.76度。上颌第一磨牙伸长0.14mm;上颌前磨牙伸长1.88mm。上颌第二磨牙也远中移动2.02mm,远中倾斜7.89度。纵向评估(正畸治疗开始至结束)显示,琼斯矫治器样本与颈带矫治器样本在下唇至E线和SNA方面存在显著差异。琼斯矫治器样本显示下唇至E线平均减少0.25mm,而颈带矫治器样本为1.20mm(P <.0212)。琼斯矫治器样本的SNA减少0.40度,而颈带矫治器样本为1.20度(P <.0093)。然而,在对上颌第一磨牙和相应的前磨牙-切牙锚固单元进行线性或角度测量时,琼斯矫治器样本和颈带矫治器样本在最终位置上没有显示出显著差异。琼斯矫治器显示出与颈带矫治器治疗样本相当的治疗效果。琼斯矫治器样本显示出有效的磨牙远中移动并维持了I类磨牙关系。琼斯矫治器的优点包括对患者配合的依赖最小、易于制作以及易于施加颊向力。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验