Immunochromatographic assays (ICAs) are also referred to as rapid tests, since they are simple and the results can be obtained within minutes after manually loading a few drops of a sample into each sample well of the test device. However, whole blood cannot be tested with ICA kits due to the visual hindrance caused by the color of red blood cells (RBCs), unless a cell-removing device such as a filter is mounted on the kits. Thus, when testing with blood, the advantage of the ICA kit is lost because of the additional time and machines required to coagulate and separate whole blood before preparing the serum. To overcome this limitation, whole-blood samples were added to a pretreatment solution to decolor the RBCs; the resulting mixtures were then loaded into the sample wells of the test device. The pretreating solution was composed of hydrogen peroxide (H(2)O(2)) to decolor the RBCs, Sag 471 (Osi Specialties) to restrain the mixture from vigorous foaming, sodium azide (NaN(3)) to inhibit the enzyme, which generates excessive foam at the beginning of decolorization, and EDTA as a chelating agent. As a result of this pretreatment, whole blood could be used with the ICA kit without reducing its simplicity and rapidity.

摘要

相似文献

1
Pretreatment of whole blood for use in immunochromatographic assays for hepatitis B virus surface antigen.
Clin Diagn Lab Immunol. 2001 Jan;8(1):9-13. doi: 10.1128/CDLI.8.1.9-13.2001.
4
PRISM hepatitis B surface antigen detection of hepatits B virus minipool nucleic acid testing yield samples.
Transfusion. 2008 Jul;48(7):1376-82. doi: 10.1111/j.1537-2995.2008.01698.x. Epub 2008 Apr 17.
5
The analytic sensitivity and mutant detection capability of six hepatitis B surface antigen assays.
Am J Clin Pathol. 2006 May;125(5):748-51. doi: 10.1309/K5EM-795V-NGGF-GBXX.
6
Risks associated with fresh whole blood and red blood cell transfusions in a combat support hospital.
Crit Care Med. 2007 Nov;35(11):2576-81. doi: 10.1097/01.CCM.0000285996.65226.A9.
9
Detection of CMV DNA: is EDTA whole blood superior to EDTA plasma?
J Virol Methods. 2008 Dec;154(1-2):210-2. doi: 10.1016/j.jviromet.2008.08.012. Epub 2008 Oct 1.

本文引用的文献

1
Evaluation of a rapid immunochromatographic test for diagnosis of dengue virus infection.
J Clin Microbiol. 1998 Jan;36(1):234-8. doi: 10.1128/JCM.36.1.234-238.1998.
2
Immunochromatographic assay for quantitation of milk progesterone.
Acta Chem Scand (Cph). 1996 Feb;50(2):141-5. doi: 10.3891/acta.chem.scand.50-0141.
5
Hydroxyl and alkoxyl radical production by oxidation products of metmyoglobin.
Free Radic Res Commun. 1993;18(1):29-41. doi: 10.3109/10715769309149911.
7
Methaemoglobinaemia.
Clin Haematol. 1981 Feb;10(1):99-122.
8
Catalase and superoxide dismutase in Escherichia coli.
J Biol Chem. 1983 May 25;258(10):6277-81.
9
Hemoglobin. A biologic fenton reagent.
J Biol Chem. 1984 Dec 10;259(23):14354-6.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验