Yip H K, Smales R J
Faculty of Dentistry, University of Hong Kong, Hong Kong, People's Republic of China.
Quintessence Int. 2000 Apr;31(4):261-6.
The purposes of this study were to compare the fluoride ion release from a freshly mixed polyacid-modified resin composite, or "compomer" (Dyract), and 3 resin-modified glass-ionomer cements (Fuji II LC, Photac-Fil, and Vitremer) and to compare the use of 3 units for measuring fluoride release.
Five specimens (3.0 x 2.7 mm) of each material were prepared. The specimens were placed in polypropylene vials with 2 mL of deionized water and stored at 37 degrees C. The solutions were replaced weekly and the levels of fluoride ions were analyzed at days 1, 7, and 30 and subsequently every 28 days for 253 days. Fluoride measurements were carried out using a fluoride ion-selective electrode connected to a pH ion-selective electrode meter. Fluoride ion release was measured in parts per million, micrograms per square centimeter, and micrograms per cubic millimeter.
Fuji II LC, Photac-Fil, and Vitremer showed high initial release values, which decreased exponentially and then showed a slow decline during the ensuing time. Dyract released significantly less fluoride ions during the first 84 days than did the 3 resin-modified glass-ionomer cements and maintained this low level of release throughout the study period. The amounts of fluoride ion release measured at any time interval varied with the units of measurement chosen, but the pattern of release remained the same.
There was a wide variation in the amounts of fluoride ions released from related products, but the patterns of release were similar and unaffected by the units of measurement used.
本研究旨在比较新混合的聚酸改性树脂复合材料(即“复合体”,Dyract)与3种树脂改性玻璃离子水门汀(Fuji II LC、Photac - Fil和Vitremer)的氟离子释放情况,并比较3种测量氟释放的单位的使用情况。
每种材料制备5个样本(3.0×2.7毫米)。将样本置于装有2毫升去离子水的聚丙烯小瓶中,在37摄氏度下储存。每周更换溶液,并在第1天、第7天、第30天分析氟离子水平,随后每28天分析一次,共持续253天。使用连接到pH离子选择性电极计的氟离子选择性电极进行氟测量。氟离子释放量以百万分之一、每平方厘米微克数和每立方毫米微克数为单位进行测量。
Fuji II LC、Photac - Fil和Vitremer显示出较高的初始释放值,这些值呈指数下降,然后在随后的时间里缓慢下降。Dyract在最初84天内释放的氟离子明显少于3种树脂改性玻璃离子水门汀,并在整个研究期间保持这种低释放水平。在任何时间间隔测量的氟离子释放量随所选测量单位而变化,但释放模式保持不变。
相关产品释放的氟离子量存在很大差异,但释放模式相似,且不受所用测量单位的影响。