Suppr超能文献

含氟材料的氟释放

Fluoride release from fluoride-containing materials.

作者信息

de Araujo F B, García-Godoy F, Cury J A, Conceição E N

机构信息

University of Texas Health Science Center at San Antonio, Department of Pediatric Dentistry 78284-7888, USA.

出版信息

Oper Dent. 1996 Sep-Oct;21(5):185-90.

PMID:9484170
Abstract

This in vitro study evaluated the amount of fluoride released from fluoride-containing materials over a period of 28 days. Six disk samples (2.06 +/- 0.06 cm2) were prepared of each material and divided at random into seven groups: Group 1: Chelon-Fil; Group 2: Chelon-Silver; Group 3: VariGlass; Group 4: Dyract; Group 5: Vitremer; Group 6: Vitremer + Scotchbond Multi-Purpose; Group 7: Fuji II LC. The cements were mixed according to the manufacturers' recommendations, placed in plastic molds, and pressed between two glass plates. Paraffined dental floss was incorporated into the cements during setting to serve as attachments. The materials in Groups 3, 4, and 5 were light cured (Heliolux) in two different positions for 40 seconds each. In Group 6, the adhesive was light cured in two different positions on both sides for 10 seconds each. The samples were stored at 100% relative humidity for 24 hours. Each sample was then suspended in individual plastic tubes containing 5 ml of deionized water and submitted to constant agitation at 25 degrees C. The water was changed every 24 hours. Fluoride release was determined at 1, 2, 3, 4, 5, 7, 14, and 28 days after buffering the solution with equal volume of TISAB. Fluoride release was measured with a fluoride ion-specific electrode (Orion 96-09) and an ionanalyzer (Orion EA 940) previously calibrated with standard solutions containing 0.05 to 5.00 micrograms F/ml. Fluoride release was expressed as ppm in solution and micrograms F/cm2. ANOVA and Student-Newman-Keuls tests were used to evaluate the data. The results revealed that Chelon-Fil released significantly (P < 0.001) more fluoride for the first 7 days than all the other products. This was followed by Fuji II LC, which exhibited significantly more fluoride release than the rest of the materials for the same 7 days. At days 14 and 28, Chelon-Fil, Dyract, and Fuji II LC released similar amounts of fluoride that were significantly greater than the other products. Group 6 (Vitremer + Scotchbond Multi-Purpose) released significantly less fluoride than the other materials at all time intervals. Fluoride release for all products at days 1 and 2 was significantly greater than the rest of the time intervals, except for Chelon-Silver, which released similar amounts of fluoride for days 2, 3, 4, and 5. Although significance for the remaining time intervals varied for all materials, all fluoride release decreased from day 1 to day 28.

摘要

这项体外研究评估了含氟材料在28天内释放的氟化物量。每种材料制备六个圆盘样本(2.06±0.06平方厘米),并随机分为七组:第1组:Chelon - Fil;第2组:Chelon - Silver;第3组:VariGlass;第4组:Dyract;第5组:Vitremer;第6组:Vitremer + Scotchbond多功能粘结剂;第7组:Fuji II LC。按照制造商的建议混合这些水门汀,放入塑料模具中,并在两块玻璃板之间压制。在凝固过程中将涂有石蜡的牙线掺入水门汀中作为附着物。第3、4和5组的材料在两个不同位置进行光固化(Heliolux),每次40秒。在第6组中,粘结剂在两侧的两个不同位置进行光固化,每次10秒。样本在100%相对湿度下储存24小时。然后将每个样本悬浮在装有5毫升去离子水的单独塑料管中,并在25℃下持续搅拌。每24小时更换一次水。在用等体积的总离子强度调节缓冲剂(TISAB)缓冲溶液后,于第1、2、3、4、5、7、14和28天测定氟化物释放量。使用氟离子特异性电极(Orion 96 - 09)和先前用含0.05至5.00微克氟/毫升标准溶液校准的离子分析仪(Orion EA 940)测量氟化物释放量。氟化物释放量以溶液中的ppm和微克氟/平方厘米表示。使用方差分析(ANOVA)和Student - Newman - Keuls检验来评估数据。结果显示,Chelon - Fil在最初7天释放的氟化物比所有其他产品显著更多(P < 0.001)。其次是Fuji II LC,在相同的7天内,其释放的氟化物比其他材料显著更多。在第14天和28天,Chelon - Fil、Dyract和Fuji II LC释放的氟化物量相似,且显著高于其他产品。第6组(Vitremer + Scotchbond多功能粘结剂)在所有时间间隔内释放的氟化物均显著少于其他材料。除Chelon - Silver在第2、3、4和5天释放的氟化物量相似外,所有产品在第1天和第2天的氟化物释放量均显著高于其余时间间隔。尽管所有材料在其余时间间隔的显著性有所不同,但从第1天到第28天,所有氟化物释放量均下降。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验