Suppr超能文献

采用³H标准效率示踪的4πβ液体闪烁光谱法对¹⁷⁷Lu进行标准化。

The standardization of 177Lu by 4pibeta liquid scintillation spectrometry with 3H-standard efficiency tracing.

作者信息

Zimmerman B E, Unterweger M P, Brodack J W

机构信息

Physics Laboratory, National Institute of Standards and Technology, Gaithersburg, MD 20899-8462, USA.

出版信息

Appl Radiat Isot. 2001 Apr;54(4):623-31. doi: 10.1016/s0969-8043(00)00316-x.

Abstract

Solutions containing the potential radiotherapy radionuclide 177Lu have been standardized at the National Institute of Standards and Technology (NIST) by 4pibeta liquid scintillation (LS) counting with 3H-standard efficiency tracing using the CIEMAT/NIST method. Confirmatory measurements were made with 4pi NaI(TI) gamma-ray spectrometry. Activity determinations were made on 4 solutions over the course of 10 months with an expanded (k = 2) uncertainty on the activity of 0.8%. Half-life measurements were carried out using the NIST "4pi" gamma ionization chamber (IC) and LS counting and gave a new value of 6.65+/-0.01 d, which is shorter than the current ENSDF-recommended value by 1.3%. Impurity analyses were performed by high-purity germanium (HPGe) gamma-ray spectrometry and indicated only the presence of 177mLu at a level of 0.02% that of the 177Lu as of the respective reference times for the four solutions. Calibration factors for the NIST IC and Vinten 671 ionization chambers were developed, as were dial settings for the NIST-maintained Capintec CRC-12.

摘要

含有潜在放射治疗放射性核素177Lu的溶液已在美国国家标准与技术研究院(NIST)通过4πβ液体闪烁(LS)计数法进行标准化,采用CIEMAT/NIST方法进行3H标准效率追踪。使用4π碘化钠(铊)γ射线能谱法进行了验证性测量。在10个月的时间内对4种溶液进行了活度测定,活度的扩展(k = 2)不确定度为0.8%。使用NIST的“4π”γ电离室(IC)和LS计数法进行了半衰期测量,得出新值为6.65±0.01天,比当前ENSDF推荐值短1.3%。通过高纯锗(HPGe)γ射线能谱法进行了杂质分析,结果表明在四种溶液各自的参考时间,仅存在含量为177Lu含量0.02%的177mLu。制定了NIST IC和Vinten 671电离室的校准因子,以及NIST维护的Capintec CRC - 1

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验