冠状动脉对比增强磁共振成像:猪体内血管内与血管外对比剂的比较

Contrast-enhanced MR imaging of coronary arteries: comparison of intra- and extravascular contrast agents in swine.

作者信息

Li D, Zheng J, Weinmann H J

机构信息

Department of Radiology, Northwestern University Medical School, 448 E Ontario St, Ste 700, Chicago, IL 60611, USA.

出版信息

Radiology. 2001 Mar;218(3):670-8. doi: 10.1148/radiology.218.3.r01mr03670.

Abstract

PURPOSE

To compare the efficacy of an intravascular contrast agent, gadomer-17, in improving magnetic resonance (MR) imaging of coronary arteries with that of an extravascular agent, gadopentetate dimeglumine, in pigs.

MATERIALS AND METHODS

Eight pigs underwent imaging after three injections: 0.20 mmol of gadopentetate dimeglumine per kilogram of body weight and 0.05 and 0.10 mmol/kg gadomer-17. Coronary images were acquired repeatedly after each injection by using an inversion-recovery-prepared segmented three-dimensional sequence with either breath holding (n = 4) or respiratory gating (n = 4). Coronary artery-to-myocardium contrast-to-noise ratios (CNRs) were compared between injections.

RESULTS

At breath-hold imaging, substantial CNR improvement over precontrast images was observed in images acquired during the first pass of gadopentetate dimeglumine in coronary arteries and up to 6 and 10 minutes after 0.05 and 0.10 mmol/kg of gadomer-17 injections, respectively. The CNR with 0.10 mmol/kg of gadomer-17 was 20% (P <.05) higher than that with gadopentetate dimeglumine at first-pass imaging. At respiratory-gated imaging, significant CNR improvement (P <.05) over precontrast images was observed in images acquired up to 10, 30, and 50 minutes after gadopentetate dimeglumine and both gadomer-17 injections, respectively. The CNR on the first images obtained after 0.10 mmol/kg gadomer-17 injection was 168% (P <.05) higher than that on the images obtained after gadopentetate dimeglumine injection.

CONCLUSION

Gadomer-17 provided greater and more persistent CNR improvements than did gadopentetate dimeglumine; further evaluation of its utility for coronary imaging in humans is warranted.

摘要

目的

比较血管内造影剂钆喷酸葡胺与血管外造影剂钆布醇在猪冠状动脉磁共振成像中的效果。

材料与方法

八头猪在接受三次注射后进行成像:每千克体重注射0.20毫摩尔钆喷酸葡胺以及0.05和0.10毫摩尔/千克钆布醇。每次注射后,使用屏气(n = 4)或呼吸门控(n = 4)的反转恢复准备的分段三维序列重复采集冠状动脉图像。比较各次注射之间冠状动脉与心肌的对比噪声比(CNR)。

结果

在屏气成像中,在钆喷酸葡胺首次通过冠状动脉期间以及分别在注射0.05和0.10毫摩尔/千克钆布醇后6分钟和10分钟采集的图像中,观察到CNR相对于造影前图像有显著改善。在首次通过成像时,0.10毫摩尔/千克钆布醇的CNR比钆喷酸葡胺高20%(P <.05)。在呼吸门控成像中,在钆喷酸葡胺和两种钆布醇注射后分别在10、30和50分钟采集的图像中,观察到CNR相对于造影前图像有显著改善(P <.05)。在注射0.10毫摩尔/千克钆布醇后获得的第一张图像上的CNR比注射钆喷酸葡胺后获得的图像上的CNR高168%(P <.05)。

结论

钆布醇比钆喷酸葡胺能提供更大且更持久的CNR改善;有必要进一步评估其在人体冠状动脉成像中的效用。