外用鼻扩张器对运动时呼吸功的影响。

Effects of an external nasal dilator on the work of breathing during exercise.

作者信息

O'Kroy J A, James T, Miller J M, Torok D, Campbell K

机构信息

Department of Health Sciences, Florida Atlantic University, Davie, FL 33314, USA.

出版信息

Med Sci Sports Exerc. 2001 Mar;33(3):454-8. doi: 10.1097/00005768-200103000-00019.

Abstract

PURPOSE

The effect of an external nasal dilator on the work of breathing (WOB) was measured during exercise in 14 untrained college students (age, 23 +/- 2.7 yr).

METHODS

Two maximal, incremental ergometer tests were performed to exhaustion. Subjects wore a placebo or an active nasal dilator strip, in random order, during each test. An esophageal balloon was placed through each of the subject's mouth into the esophagus for measurement of inspiratory elastic work (INEW), inspiratory resistive work (INRW), and expiratory resistive work (EXRW). Subjects breathed through a Hans Rudolph(R) face mask that covered both the mouth and nose during both tests. Measured variables included oxygen uptake (VO2), ventilation (VE), tidal volume (VT), frequency of breathing (f), INEW, INRW, and EXRW (work expressed in joules). An alpha level was set at P < 0.05.

RESULTS

No significant differences were found in INEW, INRW, and EXRW between conditions at 70% of VO2max (mean +/- SD; Placebo: INEW, 25.6 +/- 17.8 J.min-1; INRW, 22.4 +/- 15.8 J.min-1; EXRW, 16.7 +/- 12.3 J.min-1; Active: INEW, 24.7 +/- 12.9 J.min-1; INRW, 19.7 +/- 11.9 J.min-1; EXRW, 15.2 +/- 8.6 J.min-1; P > 0.05). No difference was found in INEW, INRW, and EXRW at maximal exercise between conditions (mean +/- SD; Placebo: INEW, 50.2 +/- 29.9 J.min-1; INRW, 67.3 +/- 42.3 J.min-1; EXRW, 102.3 +/- 78.4 J.min-1; Active: INEW, 45.7 +/- 19.6 J.min-1; INRW, 62.6 +/- 36.7 J.min-1; EXRW, 86.3 +/- 50.9 J.min-1; P > 0.05). There were no differences in VO2, VE, VT, or f between conditions.

CONCLUSION

Wearing an external nasal dilator does not significantly reduce the work of breathing during exercise.

摘要

目的

在14名未经训练的大学生(年龄23±2.7岁)运动期间,测量一种外用鼻扩张器对呼吸功(WOB)的影响。

方法

进行两次递增式力竭运动测试。在每次测试中,受试者随机佩戴安慰剂或活性鼻扩张条。通过受试者口腔将食管气囊置入食管,以测量吸气弹性功(INEW)、吸气阻力功(INRW)和呼气阻力功(EXRW)。在两次测试期间,受试者均通过覆盖口鼻的Hans Rudolph®面罩呼吸。测量变量包括摄氧量(VO2)、通气量(VE)、潮气量(VT)、呼吸频率(f)、INEW、INRW和EXRW(功以焦耳表示)。设定α水平为P<0.05。

结果

在VO2max的70%时,各条件下的INEW、INRW和EXRW无显著差异(均值±标准差;安慰剂组:INEW,25.6±17.8 J·min-1;INRW,22.4±15.8 J·min-1;EXRW,16.7±12.3 J·min-1;活性组:INEW,24.7±12.9 J·min-1;INRW,19.7±11.9 J·min-1;EXRW,15.2±8.6 J·min-1;P>0.05)。在最大运动时,各条件下的INEW、INRW和EXRW无差异(均值±标准差;安慰剂组:INEW,50.2±29.9 J·min-1;INRW,67.3±42.3 J·min-1;EXRW,102.3±78.4 J·min-1;活性组:INEW,45.7±19.6 J·min-1;INRW,62.6±36.7 J·min-1;EXRW,86.3±50.9 J·min-1;P>0.05)。各条件下的VO2、VE、VT或f无差异。

结论

佩戴外用鼻扩张器在运动期间不会显著降低呼吸功。