The self-contained breathing apparatus (SCBA) increases the expiratory pressure required to maintain high rates of ventilation, suggesting that the expiratory work of breathing (WOB) is increased; however, this has never been reported. The objective of this study, therefore, was to determine if the WOB is increased with the SCBA regulator (BA condition) compared with a low-resistance breathing valve (RV condition) during exercise. Twelve healthy male subjects underwent two randomized exercise trials, consisting of cycling at 150, 180, 210, and 240 W. Inspired and expired tidal volumes were measured using a body plethysmograph, whereas esophageal pressures were measured with an esophageal balloon. Modified Campbell diagrams were created to calculate the resistive and elastic components of WOB during inspiration and expiration. There were no differences in WOB between BA and RV conditions at 150 W. End-inspiratory and -expiratory lung volumes were elevated (p < 0.05) in the BA condition at higher ventilation rates, which increased inspiratory elastic work and decreased expiratory elastic work at 180 and 210 W (p < 0.05). At 240 W (VE=112 +/- 17 L.min-1 in the BA condition), active expiratory resistive work increased by 59% +/- 51%, inspiratory elastic work increased by 26% +/- 24%, and total WOB increased by 13% +/- 12% in the BA condition (p < 0.05). The SCBA regulator causes an increase in the active expiratory resistive work to maintain high ventilatory rates and an increase inspiratory elastic work through an elevation in lung volumes.
自给式呼吸器(SCBA)会增加维持高通气率所需的呼气压力,这表明呼吸的呼气功(WOB)增加;然而,此前从未有过相关报道。因此,本研究的目的是确定在运动过程中,与低阻力呼吸阀(RV状态)相比,使用SCBA调节器时(BA状态)WOB是否增加。12名健康男性受试者进行了两项随机运动试验,包括以150、180、210和240瓦的功率进行骑行。使用体容积描记器测量吸气和呼气潮气量,而用食管气囊测量食管压力。绘制改良的坎贝尔图以计算吸气和呼气过程中WOB的阻力和弹性成分。在150瓦时,BA状态和RV状态的WOB没有差异。在较高通气率下,BA状态的吸气末和呼气末肺容积升高(p<0.05),这在180和210瓦时增加了吸气弹性功并降低了呼气弹性功(p<0.05)。在240瓦时(BA状态下VE=112±17升·分钟-1),BA状态下主动呼气阻力功增加了59%±5%,吸气弹性功增加了26%±24%,总WOB增加了13%±12%(p<0.05)。SCBA调节器会导致主动呼气阻力功增加以维持高通气率,并通过肺容积升高增加吸气弹性功。