Suppr超能文献

作为呼吸器适配特性和适配测试准确性函数的呼吸防护

Respiratory protection as a function of respirator fitting characteristics and fit-test accuracy.

作者信息

Campbell D L, Coffey C C, Lenhart S W

机构信息

Department of Health and Human Services, Public Health Service, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, Division of Respiratory Disease Studies, Morgantown, WV 26505-2888, USA.

出版信息

AIHAJ. 2001 Jan-Feb;62(1):36-44. doi: 10.1080/15298660108984607.

Abstract

The fitting characteristics of particulate respirators are no longer assessed in the National Institute for Occupational Safety and Health respirator certification program. It is important for respirator program administrators to understand the implications of that change and the additional burden it may impose. To address that issue, a typical respirator fit-testing program is analyzed using a mathematical model that describes the effectiveness of a fit-testing program as a function of the fitting characteristics of the respirator and the accuracy of the fittesting method. The model is used to estimate (1) the respirator assignment error, the percentage of respirator wearers mistakenly assigned an ill-fitting respirator; (2) the number of fit-test trials necessary to qualify a group of workers for respirator use; and (3) the number of workers who will fail the fit-test with any candidate respirator model and thereby fail to qualify for respirator use. Using data from previous studies, the model predicts respirator assignment errors ranging from 0 to 20%, depending on the fitting characteristics of the respirator models selected and the fit-testing method used. This analysis indicates that when respirators do not necessarily have good fitting characteristics, respirator program administrators should exercise increased care in the selection of respirator models and increased care in fit-testing. Also presented are ways to assess the fitting characteristics of candidate respirator models by monitoring the first-time fit-testing results. The model demonstrates that significant public health and economic benefits can result when only respirators having good fitting characteristics are purchased and respirators are assigned to workers using highly accurate fit-testing methods.

摘要

美国国家职业安全与健康研究所的呼吸器认证计划不再评估颗粒物呼吸器的贴合特性。呼吸器计划管理人员必须了解这一变化的影响以及可能带来的额外负担。为解决该问题,本文使用一个数学模型对典型的呼吸器适合性测试计划进行了分析,该模型将适合性测试计划的有效性描述为呼吸器贴合特性和适合性测试方法准确性的函数。该模型用于估计:(1)呼吸器分配错误,即错误地为佩戴呼吸器的人员分配不合身呼吸器的百分比;(2)使一组工人有资格使用呼吸器所需的适合性测试次数;(3)使用任何候选呼吸器型号进行适合性测试时不合格从而没有资格使用呼吸器的工人数量。根据以往研究的数据,该模型预测呼吸器分配错误率在0%至20%之间,具体取决于所选呼吸器型号的贴合特性和所使用的适合性测试方法。该分析表明,当呼吸器不一定具有良好的贴合特性时,呼吸器计划管理人员在选择呼吸器型号时应更加谨慎,并在适合性测试中更加小心。本文还介绍了通过监测首次适合性测试结果来评估候选呼吸器型号贴合特性的方法。该模型表明,当只购买具有良好贴合特性的呼吸器,并使用高度准确的适合性测试方法为工人分配呼吸器时,可带来显著的公共卫生和经济效益。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验