Suppr超能文献

年轻男性组胺支气管激发试验的短期重复性。SUS研究。

The short-term repeatability of histamine bronchial testing in young males. The SUS study.

作者信息

Omland Ø, Miller M R, Sigsgaard T, Pedersen O F

机构信息

Department of Environmental and Occupational Medicine, University of Aarhus, Denmark.

出版信息

Respir Med. 2001 Apr;95(4):287-91. doi: 10.1053/rmed.2001.1036.

Abstract

We have measured bronchial responsiveness (BR) to histamine on two occasions between 5 and 24 h apart, to determine if conventional and new indices of BR are repeatable. A random sample of 29 healthy male subjects with a mean age of 19 (SD 3.44) years from a larger study repeated a Yan method test of BR, recording both partial and maximal expiratory flow volume (PEFV and MEFV) curves. From the MEFV curves log-dose slopes (LDS) for forced expiratory volume in 1 sec (FEV1), forced expiratory flow between 25% and 75% of forced vital capacity (FVC) (FEF(25-75%)), mean expiratory flow at 30% and 40% of FVC (MEF30, MEF40), and the first moment of the spirogram (alpha1) truncated at 75% and 90% of FVC were calculated, as well as the provocative dose that induces a 20% fall in FEV1 (PD20FEV1). From the PEFV curves LDS for alpha(1)75% and alpha(1)90%, and MEF30 and MEF40 were derived. Apart from MEF30 and alpha(1)90% the second test was significantly lower (P<0.05) than the first when measuring the repeatability of spirometric indices, whereas the LDS of the indices showed no significant change. The repeatability expressed as intra-class correlation coefficient (ICC) was highest for LDS FEV1 (0.87), second highest for LDS MEF40 (0.67) and LDS MEF30 (0.65). The LDS for moment indices were much less repeatable and the lowest ICC was found in all LDS indices derived from PEFV curves. Within-subject variance was not influenced by atopic status, smoking habits or recordable PD20FEV1. As tests for bronchial hyper-responsiveness (BHR) the LDS of FEV1, MEF40 and MEF30 seem to be acceptable for use in population studies.

摘要

我们在间隔5至24小时的两个时间点测量了支气管对组胺的反应性(BR),以确定传统和新的BR指标是否具有可重复性。在一项更大规模研究中,从29名平均年龄为19岁(标准差3.44)的健康男性受试者中随机抽取样本,重复进行了BR的Yan法测试,记录了部分和最大呼气流量容积(PEFV和MEFV)曲线。从MEFV曲线中计算出1秒用力呼气容积(FEV1)、用力肺活量(FVC)的25%至75%之间的用力呼气流量(FEF(25 - 75%))、FVC的30%和40%时的平均呼气流量(MEF30、MEF40)以及肺活量图在FVC的75%和90%处截断的第一矩(alpha1)的对数剂量斜率(LDS),以及引起FEV1下降20%的激发剂量(PD20FEV1)。从PEFV曲线中得出alpha(1)75%和alpha(1)90%以及MEF30和MEF40的LDS。在测量肺量计指标的可重复性时,除了MEF30和alpha(1)90%外,第二次测试显著低于第一次(P<0.05),而指标的LDS没有显著变化。以组内相关系数(ICC)表示的可重复性,LDS FEV1最高(0.87),LDS MEF40次之(0.67),LDS MEF30第三(0.65)。矩指标的LDS重复性要低得多,并且在从PEFV曲线得出的所有LDS指标中,ICC最低。受试者内方差不受特应性状态、吸烟习惯或可记录的PD20FEV1的影响。作为支气管高反应性(BHR)测试,FEV1、MEF40和MEF30的LDS似乎可用于人群研究。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验