Suppr超能文献

股骨交锁髓内钉远端锁定螺钉的应力分析

Stress analysis of the distal locking screws for femoral interlocking nailing.

作者信息

Lin J, Lin S J, Chen P Q, Yang S H

机构信息

Department of Orthopaedic Surgery, National Taiwan University Hospital, Taipei.

出版信息

J Orthop Res. 2001 Jan;19(1):57-63. doi: 10.1016/S0736-0266(00)00020-6.

Abstract

In femoral locked nailing, the distal locking screws are vulnerable to mechanical failure. Biomechanical studies have shown that the stress on these screws is substantially affected by the fit of the nail in the medullary canal. In this study, a "closed form" mathematical model based on elastic beam-column theory was developed to investigate how the nail-cortical contact, which was simulated by a linear elastic foundation, affected the stress on the distal locking screws. Providing data for the model was a construct of a fractured femur with an intramedullary locked nail loaded by an eccentric vertical load. The stress on the locking screw was analyzed as a function of the distance from the fracture to the locking screw in the distal fragment under two situations: with and without nail-cortical contact in the distal fragment. With nail-cortical contact, the screw stress decreased as the length of nail-cortical contact and the distance between the distal locking screw and the fracture site increased, but this stress contrarily increased when the nail reached the femoral region at which the screw length increased. The screw stress was much higher without nail-cortical contact than with contact and continued to increase as the nail was inserted further. The mathematical model developed here can be a convenient means of rapid stress evaluation and parametric analysis for locked femoral nailing. It may be used to improve the design of interlocking nails and surgical technique.

摘要

在股骨带锁髓内钉固定中,远端锁定螺钉容易出现机械性失效。生物力学研究表明,这些螺钉上的应力受髓内钉与髓腔匹配情况的显著影响。在本研究中,基于弹性梁柱理论建立了一个“封闭形式”的数学模型,以研究由线性弹性基础模拟的钉-皮质接触如何影响远端锁定螺钉上的应力。为该模型提供数据的是一个带有髓内带锁髓内钉的股骨骨折结构,该结构承受偏心垂直载荷。分析了在两种情况下,远端锁定螺钉的应力作为远端骨折块中从骨折处到锁定螺钉距离的函数:远端骨折块中有和没有钉-皮质接触。有钉-皮质接触时,随着钉-皮质接触长度以及远端锁定螺钉与骨折部位之间距离的增加,螺钉应力降低,但当髓内钉到达螺钉长度增加的股骨区域时,该应力反而增加。没有钉-皮质接触时的螺钉应力比有接触时高得多,并且随着髓内钉进一步插入,应力持续增加。此处建立的数学模型可作为一种便捷的手段,用于股骨带锁髓内钉固定的快速应力评估和参数分析。它可用于改进交锁髓内钉的设计和手术技术。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验