Phillips M L, Meagher C C, Johnson D L
Department of Occupational and Environmental Health, University of Oklahoma, Health Sciences Center, PO Box 26901, Oklahoma City, Oklahoma 73190, USA.
Occup Environ Med. 2001 Jul;58(7):479-81. doi: 10.1136/oem.58.7.479.
To characterise the distribution of particle size and mass of glove powder aerosol released from powdered and powder free non-sterile latex gloves under controlled conditions.
Gravimetric sampling and aerodynamic particle size analysis were performed during simulated use of gloves on a prosthetic hand in a chamber designed to minimise background particle concentrations.
Aerosol was detectable for both powdered and powder free gloves under both aggressive and non-aggressive handling conditions. Most of the particles detected had aerodynamic diameter less than 10 microm.
Powder free gloves were not entirely free of powder aerosol. Particles from both powdered and powder free gloves are sufficiently fine to penetrate into the thoracic region of the respiratory tract.