Cappozzo A, Catani F, Leardini A, Benedetti M G, Croce U Della
Istituto di Fisiologia Umana, Università degli Studi di Sassari, Sassari, Italy.
Clin Biomech (Bristol). 1996 Mar;11(2):90-100. doi: 10.1016/0268-0033(95)00046-1.
This paper deals with the experimental problems related to the reconstruction of the position and orientation of the lower limb bones in space during the execution of locomotion and physical exercises. The inaccuracies associated with the relative movement between markers and underlying bone are analysed. Quantitative information regarding this movement was collected by making experiments on subjects who had suffered fractures and were wearing either femoral or tibial external fixators. These latter devices provided frames that were reliably rigid with the bone involved, and hence the possibility of assessing the relative movement between markers mounted on the skin and this bone. Anatomical frames associated with thigh and shank were reconstructed using technical frames based on different clusters of skin markers and their rotation with respect to the relevant bone evaluated. Marker movement was also assessed in subjects with intact musculoskeletal structures using digital videofluoroscopy.
本文探讨了与下肢骨骼在运动和体育锻炼过程中在空间中的位置和方向重建相关的实验问题。分析了标记物与深层骨骼之间相对运动所产生的误差。通过对骨折且佩戴股骨或胫骨外固定器的受试者进行实验,收集了有关该运动的定量信息。这些外固定器提供了与相关骨骼可靠固定的框架,从而有机会评估安装在皮肤上的标记物与该骨骼之间的相对运动。利用基于不同皮肤标记物簇的技术框架重建了与大腿和小腿相关的解剖学框架,并评估了它们相对于相关骨骼的旋转情况。还使用数字荧光透视法对肌肉骨骼结构完整的受试者的标记物运动进行了评估。