Taylor N F, Evans O M, Goldie P A
Faculty of Health Sciences, La Trobe University, Australia.
Clin Biomech (Bristol). 1996 Dec;11(8):484-486. doi: 10.1016/s0268-0033(96)00036-8.
To determine the familiarization period required to obtain consistent measurements of the angular movements of the lumbar spine and pelvis during treadmill walking. DESIGN: An in vivo study with repeated measures every 2 min over 10 min. BACKGROUND: Walking on a treadmill can initially be an unfamiliar experience. No data were available to indicate the length of time required for treadmill familiarization prior to taking measurements of the angular movements of the lumbar spine and pelvis. The familiarization period has implications for the use of this technique in clinical testing. METHODS: The angular movements of the lumbar spine and pelvis were examined by thePEAK 3D motion measurement system in 16 untrained, normal subjects walking for 10 min on a treadmill at either self-selected or 60% of self-selected speed. RESULTS: The reliability of the angular measurements of the spine and pelvis were all greater than 0.83 (ICC) after 4 min of treadmill walking and did not appear to increase after 4 min. No changes in the amplitudes of the angular movements of the lumbar spine and pelvis could be detected after 4 min of treadmill walking, or of the absolute difference scores beyond 2 min of treadmill walking, in either normal or slow-speed walking groups. CONCLUSIONS: Angular movements of the lumbar spine and pelvis were consistent after 4 min of treadmill walking by normal subjects, both at self-selected and slow walking speeds, indicating that reliable measurements of these parameters could be taken at that time.
确定在跑步机上行走时,获取腰椎和骨盆角运动一致测量值所需的熟悉期。
一项体内研究,在10分钟内每2分钟重复测量一次。
在跑步机上行走最初可能是一种不熟悉的体验。在测量腰椎和骨盆角运动之前,没有数据表明熟悉跑步机所需的时间长度。熟悉期对该技术在临床测试中的应用有影响。
使用PEAK 3D运动测量系统,对16名未经训练的正常受试者在跑步机上以自选速度或自选速度的60%行走10分钟时的腰椎和骨盆角运动进行检查。
跑步机行走4分钟后,脊柱和骨盆角测量的可靠性均大于0.83(组内相关系数),4分钟后似乎没有增加。在正常或慢速行走组中,跑步机行走4分钟后,未检测到腰椎和骨盆角运动幅度的变化,跑步机行走2分钟后也未检测到绝对差异分数的变化。
正常受试者在跑步机上行走4分钟后,无论自选速度还是慢速行走,腰椎和骨盆的角运动都是一致的,这表明此时可以对这些参数进行可靠的测量。